BIRSS RSM-2 M350 — thixotropic R3 mix with normal setting times
Shrinkage-compensated repair mortar for bridges, tunnels, hydraulic structures and joints of precast reinforced concrete; class R3.

BIRSS RSM-2M M350 Mekh, a rapid-hardening thixotropic mix based on special cements with reinforcing fibre and sand up to 1.25 mm, is applied by shotcreting. It is used in structural repair of bridges and tunnels, hydraulic structures, columns and beams, and for filling joints between precast elements and cavities without formwork. Class R3 to GOST R 56378; compressive strength 15 MPa after one day and 35 MPa at 28 days, flexural 3.5 and 7 MPa, water impermeability W10.
| Manufacturer | BIRSS — AO Opytny Zavod Sukhikh Smesey (Experimental Dry Mix Plant), Moscow |
|---|---|
| Type | shotcrete mixes |
| Use | bridges and overpasses, tunnels and metro, hydraulic structures and dams, columns and beams, industrial buildings |
| Base | BIRSS RSM-2M M350 Mekh dry repair mix is a material based on special cements, graded fine sand, reinforcing fibre and chemical admixtures which, when mixed with water, give a rheoplastic, non-segregating, rapid-hardening thixotropic… |
| Colour | grey |
| Packaging | bags 25 / 40 kg |
| Application method | BIRSS RSM-2M M350 Mekh repair mix is recommended for structural repair of concrete and reinforced concrete structures where high compressive strength is required: elements of road bridges and tunnels; structural elements subject to dynamic loads; filling vertical and horizontal joints between precast elements; potholes and cavities without formwork in areas with increased surface quality requirements; those… |
| Application temperature | +5…+35 °C |
| Key properties | maximum aggregate size, mm: 1.25; workability grade: Pk2/4-8; workability retention, min: 40; bond strength to substrate, MPa: 2; compressive strength, MPa, not less than - 1 / 28 days 15 / 35; flexural strength, MPa - 1 / 28 days 3.5 / 7; water impermeability: W10; frost resistance: F2 400; sulphate resistance coefficient: 0.9; service temperature, °C: from -50 to +70 |
| Standards | class R3 to GOST R 56378; STO 05668056-004-2012 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Shrinkage-compensated repair mortar for bridges, tunnels, hydraulic structures and joints of precast reinforced concrete; class R3.
Cement finishing self-levelling floor M250 for residential, public and industrial premises; foot traffic after just 8 h.
Unpigmented epoxy primer for epoxy and polyurethane floors and binder for repair compounds; bond to concrete from 3.5 MPa.
Rapid-hardening flowable mix for repairing industrial floors, equipment foundations, car parks and bridges; 30 MPa after just 3 days.
Non-shrink fine-grained mix for non-structural repair and levelling of concrete on vertical and overhead areas; workability is retained for 60 minutes.
Three-component solvent-free epoxy impregnation for fresh and old concrete floors: hardens the surface and slows water evaporation.