WETISOL Ecto SF — hydraulic plug for stopping leaks
Chloride-free rapid-hardening cement mix for eliminating active leaks in concrete, brick and stone; starts to harden after 1–2 min.

Wetisol S-MP3 is a one-component polyurethane primer cured by air moisture, with high elasticity and adhesion to PVC. It is used to prepare metal, tiles, natural stone, bituminous roofs, asphalt concrete, polyurethane foam and PVC roof coverings, as well as concrete, brick and stone, before polycarbamide and polyurethane coatings. Another purpose is as an intermediate coat when overcoating WETISOL LAM 361 mastic. The primer is applied at +5…+35 °C and tolerates mineral substrate moisture of up to 8%.
| Manufacturer | Wetisol (INGRI) — OOO “Ingri” |
|---|---|
| Type | waterproofing material |
| Base | one-component polyurethane-based material, cures with air moisture |
| Colour | transparent liquid with a yellowish tint |
| Packaging | 10 kg and 19 kg bucket; 220 kg drum |
| Application method | priming before polycarbamide (and polyurethane) coatings on metal, dense mineral substrates (tiles, natural stone), non-rigid substrates (bituminous roofs, asphalt concrete, polyurethane foam), PVC roof coverings and PVC products, as well as on concrete, brick, stone; intermediate coat when overcoating WETISOL LAM 361 mastic; metal — abrasive blast cleaning to degree 2 per GOST 9.402 / Sa 2½, Rz > 60 µm, salt and pH control; tiles, stone — shot or sand blasting; PVC — washing (pressure washers permitted), drying, degreasing; by brush, velour roller (ZOGEL Z360-2241) or airless sprayer (ZOGEL ZP-1E300, ZP-4E240); pump — WETISOL S-Clean, tools — solvent 646 |
| Application temperature | ambient air and substrate +5…+35 °C (+10…+25 °C recommended); material temperature +10…+30 °C (+15…+25 °C recommended); relative air humidity 40–80%; moisture of the mineral substrate max 8 wt. %; 3 °C above the dew point |
| Curing | drying time to degree 3 max 8 h (GOST 19007); apply the topcoat after 6–12 h at +10 °C, 4–8 h at +20 °C, 3–5 h at +30 °C, no more than 3 h at temperatures above +35 °C |
| Key properties | density at 23 °C 1.05±0.05 g/cm³ (GOST 31992.1); drying time to degree 3 max 8 h (GOST 19007); adhesion to concrete in the system with WETISOL Spray 400 — 2.5 MPa (GOST 28574); cross-cut adhesion max 1 point (GOST 15140); dry residue 80 wt. % (GOST 31939); high elasticity and adhesion to PVC substrates; service temperature from −60 to +60 °C (short-term up to +90 °C) |
| Layer thickness | dry film thickness per coat 45–60 µm; 90 µm coating |
| Consumption | theoretically 150 g/m² per 90 µm; metal, bituminous and PVC substrates — 0.15 kg/m²; concrete, brick, stone — 0.25 kg/m² |
| Shelf life | 6 months from the date of manufacture in unopened undamaged original containers at +5…+25 °C |
| Standards | TU 2312-035-94613022-14 with amendment No. 1 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Chloride-free rapid-hardening cement mix for eliminating active leaks in concrete, brick and stone; starts to harden after 1–2 min.
Water-reactive polyurethane resin forming a rigid foam on contact with water: stops water inflows with pressure up to 0.5 atm and strengthens soil.
Anti-corrosion zinc-filled polyurethane primer for steel before Wetisol polyurea: tanks, bridge supports, metal roofs, ships.
Hot-spray hybrid polyurea for foundations, tanks, roofs and bridges; elongation 150–250%, spraying at +10…+40 °C.
Sprayed polyurea for foundations, tanks, roofs and bridges: a seamless membrane with 350–450% elongation, working from −60 to +90 °C.
Ethylene glycol ether flushing liquid for cleaning rigs and hoses immediately after spraying, and tools after LAM 361 mastic.