WETISOL INSEAL 180 GP — waterproofing admixture for concrete
Liquid crystalline admixture added to the concrete mix during batching; raises the watertightness grade by 3 W steps.

Immediately after spraying thermal insulation and waterproofing, the rig and hoses are flushed with WETISOL S-Wash based on ethylene glycol ethers; it is also used to clean tools after Wetisol LAM 361 mastic. The circuits of components A and B are flushed separately in two stages — first in circulation mode, then until clear product comes out. The compound is not intended for preserving equipment; WETISOL S-Clean serves this purpose. The liquid is flammable (flash point 43.3 °C) and hygroscopic, so it is not heated above 35 °C and not stored in open containers; packaging — 9 and 18 kg metal buckets.
| Manufacturer | Wetisol (INGRI) — OOO “Ingri” |
|---|---|
| Type | waterproofing material |
| Base | flushing compound based on ethylene glycol ethers |
| Colour | transparent colourless liquid with a characteristic odour |
| Packaging | 9 kg and 18 kg metal bucket |
| Application method | flushing of equipment and hoses immediately after application of sprayed thermal insulation and waterproofing, cleaning of tools after Wetisol LAM 361 mastic; switch off the heating elements before cleaning (heating units max 35 °C); clean the circuits of components A and B separately, do not mix used cleaner from different circuits, label the containers; stage 1 — drain the working fluids, pump S-Wash in circulation mode at minimum pressure until the cleaner comes out, then the hoses and spray gun; stage 2 — pump into a clean container until clear product comes out; preservation — WETISOL S-Clean (S-Wash is not intended for preservation); do not dilute with water or water-containing solvents; do not store in open containers (hygroscopic); flammable — do not heat above 35 °C |
| Key properties | density (20 °C) 0.93 g/cm³; flash point 43.3 °C; auto-ignition temperature at least 230 °C; vapour pressure (20 °C) 0.53 kPa; soluble in water; low toxicity |
| Shelf life | 2 years from the date of manufacture in unopened undamaged original containers at +10…+25 °C |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Liquid crystalline admixture added to the concrete mix during batching; raises the watertightness grade by 3 W steps.
Penetrating dry mix for old and new concrete: works from either side of water pressure and raises watertightness by 3 steps.
Acrylic gel for injection into joints, cracks and behind the structure; swells by more than 25% on contact with water, gel time is adjustable.
One-component moisture-curing primer for polyurea on concrete, metal, bituminous and other non-rigid substrates; applied from −10 °C.
Polyurea with extended curing time for bridges, road structures and the metro: allows hot asphalt laying, short-term up to +220 °C.
Cementitious coating waterproofing for tanks, pools and foundations without movement: W16 under positive and W8 under negative pressure, bond from 1.7 MPa.