SLAVYANKA coating waterproofing — bitumen-polymer mastic
Solvent-based bitumen-polymer mastic for external waterproofing of foundations, piles and tanks; applied at air temperatures from −10 °C.

Izhora polyurethane sealant consists of a white paste and a transparent viscous liquid, which are mixed with a drill right before work; after mixing the compound has a pot life of at least 6 h and polymerises on average in 48 h. It fills expansion joints and butt joints of reinforced concrete, panel joints of facades and plinths, cracks, external window and door joints, and penetrations of metal, polypropylene and polyvinyl chloride pipes. The sealant is designed for 25 % joint movement, elongates by 600 % before break and serves from −65 to +90 °C. Work is carried out at air temperatures from +5 to +40 °C, with no precipitation.
| Manufacturer | Rastro (LAKHTA, SLAVYANKA, Izhora) — ZAO “Rastro”, Bolshaya Izhora |
|---|---|
| Type | joint sealants |
| Use | joints and junctions |
| Base | two-component polyurethane construction sealant: component 1 — white paste (can be tinted), component 2 — transparent viscous liquid from light yellow to brown |
| Colour | standard: white 01 (RAL 1013), grey 02 (RAL 7046), light grey 09 (RAL 7038); to order: light blue, brick red, green, pink, yellow, lilac |
| Packaging | 12.5 kg kit: component 1 — 11.25 kg plastic euro bucket, component 2 — 1.25 kg plastic container (placed inside the bucket) |
| Application method | remove loose pieces, crumbling concrete and, if necessary, old sealant; treat the joint walls with a milling cutter to a minimum filling width of 10 mm; clean with a disc brush and compressed air, dry and heat with a torch; working temperature of the sealant not lower than the air temperature; pour all of component 2 into component 1 and mix for 6…8 min with a low-speed drill of at least 1.2 kW (paddle 80 mm); place a foamed polyethylene backer rod; apply with a spatula in a layer of at least 3 mm per pass; optimum joint depth to width ratio 1 : 3; do not apply on surfaces with free moisture; dilution is not permitted; do not use on bitumen and bitumen-polymer substrates |
| Application temperature | air +5…+40 °C, no precipitation (below +5 °C — Izhora “Winter”) |
| Curing | pot life at least 6 h at (20±2) °C; full polymerisation on average 48 h |
| Key properties | pot life at (20±2) °C at least 6 h; joint movement capability 25 %; consistency 30 mm; sag resistance (20±2 °C) 2 mm; cohesive failure; nominal tensile strength at break at 20 °C 0.5 MPa; elongation at break (dumbbell specimens, 20 °C) 600 %; Fraass breaking point −65 °C; nominal stress at 100 % elongation 0.5 MPa; bond strength to concrete 0.6 MPa, to metal 0.5 MPa; water absorption over 24 h 0.5 % by weight; density 1.4±0.1 kg/l; service −65…+90 °C; UV resistance; compliance with GOST 25621-83 |
| Layer thickness | layer at least 3 mm per pass; joint width at least 10 mm |
| Consumption | 0.27 kg/linear m (joint 24 mm × layer 8 mm); R = A × B × ρ / 1,000 (ρ ≈ 1.4 kg/l) |
| Shelf life | 12 months from the date of manufacture; store at up to +30 °C in closed rooms or under a canopy, in stacks of no more than 5 tiers |
| Standards | TU 5772-026-11149403-2013; compliance with GOST 25621-83 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Solvent-based bitumen-polymer mastic for external waterproofing of foundations, piles and tanks; applied at air temperatures from −10 °C.
Two-component polyurethane sealant for expansion and panel joints, reinforced concrete joints and pipe penetrations; movement capability 25 %.
Elastic injection resin for sealing dry and damp cracks, joints and butt joints, including moving ones; viscosity 150 mPa·s.
Penetrating cement mix for foundations, basements and tanks that raises the water-tightness grade of concrete by 4…6 steps.
Rapid-hardening cement hydraulic plug for stopping active leaks through cracks, joints and holes; sets in 1–3 min.
Winter polyurethane mastic for foundations, car parks and wet rooms: applied at air temperatures from −20 to +10 °C.