TSVES-MO — zinc silicate primer for hot surfaces up to +400 °C
Moisture-curing zinc silicate primer for furnaces, boilers and heated pipelines, including those operating under thermal insulation.

Unlike the basic TSINEP, this primer contains at least 80 % metallic zinc in the coating, which corresponds to level 2, type II per SSPC Paint 20. It is used only as a primer coat in systems for steel structures, bridges, chemical plants, marine and port structures. It is overcoated with IZOLEP-mio, POLITON-UR, POLITON-UR (UV), ALUMOTAN and epoxy, polyurethane and acrylic based enamels, and is suitable under PLAMCOR fire protection. The coating is resistant to fresh and sea water, salt solutions and petroleum products.
| Manufacturer | VMP — AO “NPKh VMP”, Yekaterinburg |
|---|---|
| Type | zinc-rich primers |
| Use | steel structures, bridges, chemical plants, marine and port structures |
| Base | epoxy resin with zinc powder, high solids content; two-pack, polyamide hardener |
| Colour | grey (shade not standardised), matt |
| Packaging | base — metal pails 10 l and cans 1 l; hardener — metal cans 3 l and 0.25 l |
| Application method | airless spray (nozzle 0.015–0.021″, 15–25 MPa), air spray, brush, roller (stripe coating); 1–2 coats; thinner SOLV-EP, 646, 647, 648 up to 5 % by weight; base:hardener 100:5.5 by weight, 6:1 by volume |
| Application temperature | air from 0 to +40 °C (down to −5 °C permitted), relative humidity max. 85 %; surface at least 3 °C above the dew point, not above +40 °C; material not below +15 °C |
| Drying | to degree 3 — 2 h at 20 °C; overcoating at 20 °C — not earlier than 4 h, maximum 1 year; before service in aggressive media — at least 7 days |
| Key properties | metallic zinc content of the coating — at least 80 % (SSPC Paint 20, level 2, type II), volume solids — 61 %, non-volatile matter by weight — 83–86 %, density — 2.45–2.65 g/cm³, adhesion (GOST 31149) — max. 1 point, heat resistance — 120 °C, pot life at 20 °C — at least 12 h, resistant to sea and fresh water, salt solutions, crude oil and petroleum products |
| Compatible materials | topcoats: IZOLEP-mio, POLITON-UR, POLITON-UR (UV), ALUMOTAN, epoxy, polyurethane, acrylic, vinyl-epoxy and chlorinated vinyl based enamels; primer under PLAMCOR fire protection |
| Shelf life | 18 months |
| Standards | TU 20.30.12-022-12288779-2018; SSPC Paint 20 (level 2, type II); conclusion of NPO “Lakokraspokrytie” (Khotkovo) |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Moisture-curing zinc silicate primer for furnaces, boilers and heated pipelines, including those operating under thermal insulation.
Modified acrylate primer-enamel for metal and concrete without a separate primer, applied in frost down to −25 °C, RAL colours.
Fast-drying epoxy coating with zinc phosphate for painting steel structures and equipment on automatic lines.
Moisture-curing polyurethane enamel — an intermediate coat over zinc primers for bridges, steel structures and oil and gas, applied from −15 °C.
The finish coat of the IZOLEP-WP waterproofing system for bridge superstructure slabs: a polyurethane enamel resistant to weathering and ultraviolet.