Kalmatron-Inzhekt — cementitious injection mix
Dry cementitious injection mix for cut-off waterproofing of masonry and concrete, filling voids and static cracks; watertightness W10.

Gidrobeton SRG-1 is a dry repair mix based on Portland cement with aggregate up to 5 mm and chemically active reagents, applied with a trowel or mason’s trowel to moistened concrete, reinforced concrete, brick and rubble masonry. It is used to waterproof joints, junctions and screeds, including in tanks and treatment plants. At 28 days it reaches at least 50 MPa in compression and 1.5 MPa bond to concrete; watertightness is at least 12 atmospheres, frost resistance 200 cycles.
| Manufacturer | Kalmatron — OOO “Kalmatron-SPb”, Saint Petersburg |
|---|---|
| Type | thixotropic repair mortars |
| Use | tanks and treatment plants, floors |
| Base | dry mix: Portland cement, mineral aggregate up to 5 mm (granite screenings, quartz sand), a complex of patented chemically active reagents; cement-based waterproofing repair compound |
| Colour | grey (free-flowing grey powder) |
| Packaging | bags of (25±0.25) kg |
| Application method | the substrate must be clean and sound: remove plaster, paint, whitewash, loose and delaminated concrete down to “sound” concrete (with a rotary hammer), dust, dirt and oils; clean exposed rebar of concrete around its full circumference for 20 mm and of rust; saturate the surface with water, remove the excess with a rag; water 130–140 ml per 1 kg (3.2–3.5 l per 25 kg), mixing with a mixer or in a mortar mixer for 3–5 min; if workability is lost, remix, adding water is prohibited; applied with a trowel, spatula or mason’s trowel to a moistened surface; on horizontal and vertical surfaces of concrete, reinforced concrete, brick and rubble masonry, for waterproofing joints and junctions, waterproofing screeds |
| Application temperature | substrate +5…+25 °C; mortar not below +5 °C (in cold weather — warm water not above +35 °C) |
| Curing | moist curing for 3 days: wet with water every 3–4 h starting immediately after setting; protect from direct sun, rapid drying, draughts, temperature fluctuations and rain; the screed can be walked on after 12–24 h |
| Key properties | watertightness at least 12 atmospheres; frost resistance at least 200 cycles; compressive strength at 28 days at least 50 MPa; flexural strength at 28 days at least 3.5 MPa; adhesion to concrete at least 1.5 MPa; maximum aggregate size 5 mm; working time 30–40 min from mixing; service temperature -60…+130 °C |
| Shelf life | 6 months in undamaged original packaging; covered dry room, air humidity no more than 70 %, not below +5 °C |
| Standards | TU 5745-009-54282519-2008 “Cement-based waterproofing repair compounds” (amendment No. 1); GOST R 56378-2015; declaration ROSS RU D-RU.PA01.V.20373/19 valid until 10.02.2029; expert opinion No. 04E.0312.251 of 13.03.2012 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Dry cementitious injection mix for cut-off waterproofing of masonry and concrete, filling voids and static cracks; watertightness W10.
Non-shrink class R4 mix for repairing reinforced concrete by placing in formwork and for high-strength screeds; watertightness W20, F1 600.
Rapid-hardening non-shrink mix for grouting columns, equipment and bridge bearings at air temperatures down to −10 °C.
Thixotropic non-shrink class R3 mix for repairing and levelling concrete and reinforced concrete structures; watertightness W18.
Cementitious compound for rebar corrosion protection and as a bonding layer before repair mortars; bond to metal at least 2.5 MPa.
Self-compacting cementitious mix for grouting equipment and steel structures, installing anchors and repair; 70 MPa compressive at 28 days.