IZOLEP-primer — epoxy primer with zinc phosphate and micaceous iron oxide
High-build fast-drying epoxy primer for bridges, steel structures and oil and gas; categories C1–C5, CX and Im3 per GOST 34667.

A two-component epoxy paint with an aliphatic polyamine hardener: in a fire the coating intumesces and protects the steel. The fire resistance rating is up to 90 minutes. PLAMCOR-3 is designed for the open atmosphere, including highly corrosive atmospheres, and lasts at least 20 years in such conditions. The material holds an MGSU conclusion on seismic resistance as well as EAEU and NSOPB certificates.
| Manufacturer | VMP — AO “NPKh VMP”, Yekaterinburg |
|---|---|
| Fire protection performance | fire resistance up to 90 minutes |
| Application | steel structures |
| Service conditions | atmosphere, incl. highly corrosive; open atmosphere |
| Base | epoxy base + aliphatic polyamine hardener; solvent-borne, two-pack, intumescent |
| Colour | grey (shade not standardised) |
| Packaging | kit: base and hardener in metal buckets |
| Application method | airless spray (nozzle ≥ 0.047″, ≥ 25 MPa), brush/roller |
| Application temperature | from −5 to +40 °C, relative humidity ≤ 80 % |
| Drying | to degree 3 — no more than 10 h; between coats — at least 12 h; before enamel — from 24 h to 1 month; full — at least 7 days (20 °C) |
| Compatible primers and topcoats | enamels POLITON-UR (UV), VINIKOR-62, ALISTERUS 3105, polyurethane, vinyl-epoxy; primers TSINEP, IZOLEP-primer, IZOLEP-mastic, GF-021, TSINOTAN, TSVES |
| Shelf life | 24 months |
| Standards | TU 20.30.22-087-12288779-2021; GOST 15150; GOST 9980.5; GOST 19007; ASTM D 3359; EAEU and NSOPB certificates |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
High-build fast-drying epoxy primer for bridges, steel structures and oil and gas; categories C1–C5, CX and Im3 per GOST 34667.
Two-component primer-enamel with zinc phosphate: one coating instead of a primer and an enamel for C2–C5 atmospheres per ISO 12944, any RAL colour.
Acrylic primer-enamel for steel structures, bridges and power facilities; UV-resistant, applied down to −5 °C.
Epoxy intumescent coating for steel structures at oil and gas facilities: hydrocarbon regime, fire resistance rating up to 120 minutes.
High-build epoxy coating for tanks and pipelines with crude oil, fuel oil and bottom water; predicted service life 20 years.
Moisture-curing enamel with micaceous iron oxide — an intermediate coat over zinc primers for bridges, oil and gas, chemical plants and hydraulic structures.