OGNEZA-M-KOR seal (incl. with adhesive layer)
Non-combustible silica roll seal (NG, KM0) for air duct and chimney flanges and for gaps in fire-rated glazing.

On roofs, OGNEZA-OKM is used to form fire breaks, as well as around the perimeter of smoke exhaust elements and skylights. The black one-component paste on a polymer binder with fire retardants protects the bituminous or acrylic waterproofing layer, seams and joints; the coating is non-combustible per GOST 30244, class KM0. The mastic can be applied from −20 °C, but not during precipitation. It is incompatible with a number of PVC and TPO membranes, so the roofing material must be checked in advance. The service life is at least 15 years.
| Manufacturer | OGNEZA — OOO “OGNEZA”, St Petersburg |
|---|---|
| Fire protection performance | NG per GOST 30244; KM0 |
| Application | fabrics, roofing and other materials |
| Service conditions | service temperature from −40 to +60 °C |
| Base | paste on a polymer binder solution with fire retardants; one-component |
| Colour | black |
| Packaging | 20 kg |
| Application temperature | from −20 to +40 °C, relative humidity ≤ 80 %; no precipitation |
| Drying | between coats 24 h at 20 °C |
| Compatible primers and topcoats | compatible with TECHNONICOL Uniflex, Stekloizol R and other roofing materials; not compatible with some PVC and TPO membranes — selection on request |
| Shelf life | 12 months |
| Standards | TU 20.30.12-029-92450604-2020; GOST 30244; SP 7.13130.2013; SP 2.13130.2012; SP 17.13330.2017 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Non-combustible silica roll seal (NG, KM0) for air duct and chimney flanges and for gaps in fire-rated glazing.
Water-based intumescent paint for timber structures inside buildings — rafters, attics, mansards; fire protection performance group I and II.
Mineral wool board pre-coated with OGNEZA-GT sealant for combined and large cable penetrations; IET 60–180 minutes.
Split steel cable penetration with an intumescent insert for single cables and bundles through walls and floors; IET 180.
Water-soluble fire and bio-protective impregnation for timber indoors and outdoors without direct precipitation; groups I and II per GOST R 53292.
Self-priming fire-retardant varnish for timber, including parquet and facades: groups I and II, G1, V1, D2, T2, RP1, UV resistance.