Non-sparking antistatic magnesia self-levelling floor for workshops and warehouses, resistant to petroleum products, combustibility class NG.

The AMSh magnesia-shungite screed performs a protective radio-shielding function and is antistatic at the same time: specific surface and volume electrical resistance is 10⁶ per GOST 12.4.124-83. It is used together with ShT-1 plaster. Compressive strength is at least 20 MPa, flexural strength 6 MPa, combustibility class NG, site foot traffic after 8–10 hours.
| Manufacturer | ALFAPOL — OOO “ALFAPOL”, Saint Petersburg |
|---|---|
| Type | floor material |
| Use | production halls, antistatic/conductive |
| Base | Magnesia-shungite protective radio-shielding screed B25 Rk1 |
| Packaging | Dry mix ALFAPOL® AMSh is supplied in 25 kg bags. The gauging liquid (natural bischofite) is supplied in drums or canisters of various sizes. |
| Application temperature | Application temperature: from +10°C to +25°C |
| Curing | Site foot traffic possible under normal conditions* after: 8-10 hours |
| Key properties | Compressive strength at 28 days, min.: 20 MPa; Flexural tensile strength at 28 days, min.: 6 MPa; Bond strength to concrete, min.: 1 MPa; Thermal conductivity: 0.96 W/m °C, specific volume electrical resistance per GOST 12.4.124-83: 10^6 Ohm-m, specific surface electrical resistance per GOST 12.4.124-83: 10^6 Ohm; Corrosion resistance, GOST 27677-88: petrol, mineral oil; Radiation safety standard (NRB-99/2009): class 1; Combustibility class, GOST 30244-94: NG (non-combustible); Max. aggregate size: 3 mm |
| Layer thickness | Layer thickness, mm: 15 - 40 |
| Consumption | Material consumption per 10 mm layer: 17 kg per 1 m² |
| Shelf life | Guaranteed shelf life of the dry mix under normal conditions is 6 months from the date of manufacture. |
| Standards | TU 5745–001–82166262–2001; combustibility class per GOST 30244-94 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Non-sparking antistatic magnesia self-levelling floor for workshops and warehouses, resistant to petroleum products, combustibility class NG.
Radiation-shielding barite screed on a composite binder for X-ray rooms and other premises with radiation sources.
Clear gloss polyurethane sealer that improves the chemical resistance of mineral and polymer industrial floors.
Magnesia concrete floor with crushed marble for workshops and warehouses: it does not spark, dissipates static charge and resists petrol and mineral oil.
Two-component epoxy primer for mineral substrates before polymer coatings and a base for quartz-filled putty.
Versatile non-sparking "liquid topping" for hardening concrete, designed for significant mechanical impact.