Supply across Uzbekistan and to Kyrgyzstan, Tajikistan and Turkmenistan +998 93 815 00 53 Telegram sale@coatix.uz
Elakor-ED Antistatic Self-levelling Floor (AST-7, AST-6) — epoxy antistatic floor
ELAKOR

Elakor-ED Antistatic Self-levelling Floor (AST-7, AST-6) — epoxy antistatic floor

Two modifications of one epoxy floor solve different tasks under SP 29.13330.2011: AST-7 provides static-dissipative and conductive coatings, AST-6 conductive coatings with a resistance to ground of 5×10⁵–10⁶ Ω versus 5×10⁵–10⁷ Ω for AST-7. The coating is non-sparking, specific surface resistance is less than 10⁹ Ω, compressive strength 78 MPa, flexural strength 45 MPa. The floor is used in the electronics industry, server rooms, diagnostic rooms and operating theatres, laboratories, cleanrooms and warehouses of flammable substances.

Specifications

ManufacturerElakor — OOO “TEOKHIM-PROM”, Moscow Region
Typeepoxy floors
Useproduction workshops, warehouses and logistics, retail and public premises, chemically resistant, antistatic/conductive
Basecoloured two-component epoxy compound; epoxy resin, hardener, fillers, functional additives, pigments
Colourcoloured
Packaging“A” + “B” = kit 21.6 kg + 3.6 kg = 25.2 kg
Application methodAntistatic self-levelling floors on concrete, sand concrete, cement screeds, over antistatic primer. Concrete not lower than M200, cured for at least 28 days, moisture not more than 4 wt%, evenness – not more than 4 mm under a 2 m straightedge, slope not more than 0.5%; waterproofing against groundwater; screed separated by a damping strip. Spreading with a squeegee rake with a notched blade or a notched trowel, rolling with a spiked roller; paint-on version – by roller (12-14 mm nap). Relative air humidity not more than 80%; surface 3°C above the dew point; joints with movement to be repeated in the coating. For use indoors and “under a canopy”.
Application temperaturesurface and air: optimum +15°C…+22°C; permissible +5°C…+25°C; materials: optimum +15°C…+20°C, permissible +15°C…+25°C
Curingpot life on the surface at (20±2)°C at least 40 min; drying to degree 3 at (20±2)°C not more than 10 h; working time of the mixed material on the surface not more than 30 minutes
Key propertiesA:B ratio 6:1; solids content 100%; density 1.55 kg/l; ultimate compressive strength 78 MPa; flexural strength 45 MPa (GOST 4648-2014, ISO 178:2010); tensile strength 24.7 MPa; adhesion to glass not more than 1 point; impact strength (U-2M) 60 cm; flexibility (bend test) 10 mm; Shore D at 28 days 83-85; gloss at 60° 87-90%; specific weight loss by wear (GOST 20811, method B) 12.1 g/m²; Taber abrasion SC-10, 1.0 kg, 28 days – 29 mg; specific surface electrical resistance (Rs) AST-7, AST-6 less than 10^9 Ω (GOST IEC 61340-4-1-2017); resistance Rg “surface – earthing system” with an antistatic layer thickness of not more than 1.5 mm: AST-7 (V=100 V) 5x10^5-10^7 Ω, AST-6 (V=10 V) 5x10^5-10^6 Ω; conventional lightfastness at least 100 h; resistance to water and xylene at least 48 h, butyl acetate at least 24 h; fire hazard class KM2; chemical resistance: water, salt and alkali solutions of any concentration, acid solutions up to 10-20%, oils and fats of all kinds, organic solvents, petrol, diesel fuel
Layer thicknessthe Rg resistance is specified for an antistatic layer thickness of not more than 1.5 mm
Consumption1.55 kg (A+B) per 1 m² at a layer thickness of 1 mm
Shelf life8 months in the manufacturer's original packaging; store and transport at temperatures from +5° to +25°C
StandardsSpark safety test report for a 2 mm thick coating; Spark safety test report for a 0.25 mm thick coating; State registration certificate “Elakor-ED”, Customs Union; Fire safety certificate “Elakor-ED Antistatic Self-levelling Floor”; Comprehensive tests of “Elakor-ED” coatings; NIKIMT report on decontaminability and radiation resistance “Elakor ED”; ROSTEST letter “Elakor-ED”

Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.