Supply across Uzbekistan and to Kyrgyzstan, Tajikistan and Turkmenistan +998 93 815 00 53 Telegram sale@coatix.uz
ET LSTK structural fire protection for light-gauge thin-walled steel structures
TIZOL

ET LSTK structural fire protection for light-gauge thin-walled steel structures

Light-gauge thin-walled steel structures (LSTK) are protected with a separate TIZOL system, ET LSTK. It is based on MBOR-F basalt material on PLAZAS adhesive compound, while EURO-LIT board is used for I-sections and Z-profiles. Fire resistance ratings are R15–R90; NSOPB certificates have been issued for LSTK and separately for Z-profiles. Applications include residential buildings, including those of 6 storeys and above, warehouses and long-span structures; the warranty service life is at least 25 years.

Specifications

ManufacturerTIZOL — AO TIZOL, Nizhnyaya Tura
Fire protection performanceR15–R90
Applicationsteel structures
BasePLAZAS adhesive compound + MBOR-F 5–26 mm; for I-sections and Z-profiles — EURO-LIT board
StandardsTU 23.99.19-013-08621635-2020; TU 23.99.19-018-08621635-2020; TU 5762-011-08621635-2009; TR 48588528-LSTK-2022

Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.

Other materials by TIZOL

TIZOL

ET VENT — fire insulation for air ducts

Air duct fire protection system of foil-faced basalt MBOR F on PLAZAS adhesive compound: fire resistance from 30 to 240 minutes.

Price on request