INDASTRO LEVELINE FK891 curing compound for freshly laid concrete — solvent-free
Water-based polyurethane-acrylic curing compound for fresh concrete and toppings in workshops, warehouses and outdoor areas; dries in up to 3 hours at +20 °C.

The water-based primer on an acrylic dispersion prepares a concrete substrate for cement and polymer-cement coatings — self-levelling floors, screeds, repair compounds and toppings. It is applied by brush or roller onto dry, sound, dust-free concrete, indoors only, at temperatures from +5 to +35 °C. The formula with an antiseptic has an antibacterial effect, and the primer dries tack-free in 60 minutes. Packaging — 10 kg canisters.
| Manufacturer | INDASTRO — OOO “Sedrus” |
|---|---|
| Type | floor primers |
| Use | production workshops, warehouses and logistics |
| Base | polymer (acrylic) dispersion, antiseptic, water |
| Packaging | plastic canisters 10 kg, 60 per pallet |
| Application method | brush or roller onto dry, sound, dust-free concrete before cement and polymer-cement coatings (self-levelling floors, screeds, repair compounds, toppings); indoors only |
| Application temperature | substrate +5…+35 °C; application +5…+35 °C |
| Curing | tack-free drying 60 min |
| Key properties | Non-volatile content at least 12%; frost resistance in storage at least 5 cycles; antibacterial formula |
| Consumption | 0.1-0.25 kg/m2 |
| Shelf life | 12 months; storage +5…+35 °C |
| Standards | manufacturer's TU; SP 29.13330.2011, SP 71.13330.2017 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Water-based polyurethane-acrylic curing compound for fresh concrete and toppings in workshops, warehouses and outdoor areas; dries in up to 3 hours at +20 °C.
Thixotropic R4 mortar for repairing high-strength concrete and reinforced concrete of B50 and above; 70 MPa at 28 days, water impermeability W20.
Flowable R4 mortar for structural repair of B60 concrete and above; at least 35 MPa after 24 hours and 80 MPa after 28 days.
Cementitious grout for installing equipment, columns, joints and anchors at low temperatures; 10 MPa after 6 hours at −10 °C, 50 MPa at 28 days.
Pourable hardening mortar for fresh concrete and for repairing worn floors in workshops and warehouses; abrasion class AR1 to EN 13892-4.
Non-combustible non-sparking screed for levelling substrates in workshops and warehouses with explosion-safety requirements; walkable after about 12 hours.