OGNEZA-PO-PROF dry fire-retardant impregnation (concentrate)
Dry concentrate of fire-retardant impregnation for timber, diluted with water 1:3; groups I and II per GOST R 53292, 25 kg bags.

Unlike the water-based products of the range, OGNEZA-UM-D is made on an organic solution of acrylic copolymers with fire retardants and heat-expanding fillers. It protects timber and concrete, providing fire protection performance groups I and II and class KM1, so it is suitable for wall finishing in schools and halls. The coating is wear-resistant and antistatic; it is used on escape routes and stairs, including in rooms with high humidity. A separate version is intended for facades; the paint can be applied from −10 °C.
| Manufacturer | OGNEZA — OOO “OGNEZA”, St Petersburg |
|---|---|
| Fire protection performance | fire protection performance groups I and II; KM1 |
| Application | timber, concrete and reinforced concrete |
| Service conditions | indoors and outdoors (facade version), incl. rooms with high humidity; service temperature from −40 to +60 °C |
| Base | dispersion of fire retardants and heat-expanding fillers in an organic solution of acrylic copolymers |
| Colour | white to grey |
| Packaging | 3 kg, 20 kg |
| Application method | brush, roller, air spray gun; thinning with R-4 ≤ 5 % |
| Application temperature | from −10 to +40 °C, relative humidity ≤ 80 % |
| Drying | between coats 2–4 h; coating formation — 7 days |
| Compatible primers and topcoats | priming of the surface (on timber — water-dispersion primer) |
| Shelf life | 12 months |
| Standards | TU 2313-003-92450604-2012 with amendment 4 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Dry concentrate of fire-retardant impregnation for timber, diluted with water 1:3; groups I and II per GOST R 53292, 25 kg bags.
Split steel cable penetration with an intumescent insert for single cables and bundles through walls and floors; IET 180.
Non-combustible silica roll seal (NG, KM0) for air duct and chimney flanges and for gaps in fire-rated glazing.
Mineral wool board pre-coated with OGNEZA-GT sealant for combined and large cable penetrations; IET 60–180 minutes.
Clear water-soluble impregnation for timber without decorative finish — rafters, roofs, scaffolding; groups I and II per GOST R 53292.
Split steel collar with an intumescent insert for plastic pipes in walls and floors; EI 180, up to EI 240 according to the manufacturer.