Ultra-fast hydraulic plug for active leaks, mixed with cold water from +5 °C; at +20 °C setting is complete within 1 min.

SLAVYANKA insulating mastic is chosen when an underground structure needs not only waterproofing but also protection against soil corrosion, electrocorrosion and stray currents. It is used to coat trunk pipelines, the outside of tanks, foundations and other underground structures, welds and steel element entry points. The coating elongates by 500 %, withstands an impact of 6.0 J at +20 and −40 °C, resists 20 % solutions of sulphuric acid and caustic soda and complies with GOST R 51164-98. The mastic can be applied at air temperatures from −10 to +50 °C if the surface is heated to at least +5 °C.
| Manufacturer | Rastro (LAKHTA, SLAVYANKA, Izhora) — ZAO “Rastro”, Bolshaya Izhora |
|---|---|
| Type | mastics and liquid membranes |
| Use | foundations and basements, tanks and pools |
| Base | one-component cold-applied solvent-based bitumen-polymer mastic (bitumen, solvent, polymers, filler, rheological additives) |
| Colour | black |
| Packaging | metal buckets of 10, 20, 25 kg; 50 kg metal drums |
| Application method | clean metal with brushes, sandblasting or a grinder, repair concrete; remove moisture by heating; at sub-zero temperatures heat the surface above +5 °C; if the mastic has thickened, dilute with solvents up to 20 %; mix thoroughly; vertical surfaces — spatula, roller or airless spraying, horizontal surfaces — by pouring; reinforcement with glass fabric or polyester; in hot weather in coats of no more than 0.5 mm in 4…5 passes |
| Application temperature | air −10…+50 °C; surface at least +5 °C; mastic not lower than +15 °C |
| Curing | tack-free for a 2 mm coat 24 h (20±2 °C, relative humidity not more than 60 %); rain resistance after 1 h; adhesion check not earlier than after 48 h |
| Key properties | elongation at break 500 %; solids content 70 %; density 1.1 kg/dm3; bond strength to concrete 0.4 MPa (+20 °C), to metal 0.8 MPa (+20 °C) and 2.0 MPa (−15 °C); Fraass breaking point −30 °C; heat resistance +110 °C; water-tightness at 0.03 MPa for 10 min — no wet spot; chemical resistance: 20 % H2SO4, 20 % NaOH, 3 % sea salt — resistant; impact strength 60 kgf/cm (6.0 J) at +20 and −40 °C; transition resistance after 72 h in 3 % NaCl 10^10 Ohm·m²; dielectric continuity — no breakdown at 5 kV/mm |
| Layer thickness | recommended 2 mm dry film |
| Consumption | 1.57 kg/m² per 1 mm dry film |
| Shelf life | 3 years from the date of manufacture; store at no higher than +50 °C, away from direct sunlight and heating appliances |
| Standards | TU 5775-016-11149403-2006; compliance with GOST R 51164-98; G4, V3, RP4 (NPB 244-97) |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Ultra-fast hydraulic plug for active leaks, mixed with cold water from +5 °C; at +20 °C setting is complete within 1 min.
Winter polyurethane mastic for foundations, car parks and wet rooms: applied at air temperatures from −20 to +10 °C.
Rigid low-viscosity polyurethane resin for bonding cracks and joints and restoring the load-bearing capacity of concrete; 80 MPa compressive.
Two-component polyurethane sealant for expansion and panel joints, reinforced concrete joints and pipe penetrations; movement capability 25 %.
Cold bitumen-polymer mastic for repairing any roofs and building mastic roofs; elongation 1,500 %, service from −60 to +110 °C.
Winter polyurethane sealant for expansion and panel joints, applied at air temperatures from −20 to +15 °C.