Supply across Uzbekistan and to Kyrgyzstan, Tajikistan and Turkmenistan +998 93 815 00 53 Telegram sale@coatix.uz
LOGICBASE V-SL (W) PVC waterproofing membrane — for foundations and tunnels
TECHNONICOL

LOGICBASE V-SL (W) PVC waterproofing membrane — for foundations and tunnels

LOGICBASE V-SL (W), an unreinforced membrane of extruded PVC, is designed for waterproofing underground parts of buildings, metro tunnels, underground car parks and inverted roofs. It is also laid in municipal solid waste landfills, sludge ponds, artificial ponds and water storage tanks. The membrane is absolutely watertight at a pressure of 1 MPa for 24 h, does not let roots through, has low permeability to radon and methane, and in 15% solutions of salts, alkali and acids changes its properties by not more than 10%. The yellow-and-black signal layer reveals damage during installation.

Specifications

ManufacturerTECHNONICOL — OOO “Zavod Logicroof”, Ryazan
Typeroll materials and membranes
Usefoundations and basements, tunnels and metro, roofs, tanks and pools
Baseunreinforced polymer roll material of extruded PVC with fillers and process additives; signal layer: face side yellow, back side black
Colourface side yellow (signal layer), back side black
Packagingrolls 20 or 25 m × 2.05 or 2.15 m, each in opaque polyethylene film, on wooden pallets
Application methodwaterproofing of underground parts of buildings and structures, metro tunnels, underground car parks, inverted roofs; isolating layer for municipal solid waste landfills, sludge ponds, lagoons, artificial ponds and water storage tanks; the signal layer reveals damage during installation; seams — hot-air welding
Key propertiesmaximum tensile force lengthwise at least 16 MPa, crosswise at least 15 MPa (GOST 31899-2-2011, method B); elongation 350% ±20%; nail-shank tear resistance at least 150 N; low-temperature flexibility not higher than −35 °C (GOST EN 495-5-2012); flexibility temperature on a bar R = 5 mm not higher than −45 °C; watertightness at 1 MPa for 24 h — absolute (GOST EN 1928-2011, B); change in linear dimensions at 80 °C over 6 h not more than 2%; resistance to dynamic puncture at sub-zero temperatures — not higher than −30 °C; welded seam peel strength at least 300 N/50 mm, tensile strength at least 600 N/50 mm; impact resistance on a hard substrate at least 700; 1400 mm, on a soft substrate at least 1000; 1800 mm; static puncture resistance at least 20 kg; water absorption not more than 0.1%; friction coefficient of concrete on the membrane 0.6; roots do not penetrate; long-term compressive strength (48 h) 7 MPa; chemical resistance in 15% solutions of NaCl, Ca(OH)2, H2SO3, H2SO4 — change in properties not more than 10%; radon diffusion coefficient not more than 5.5·10⁻¹¹ m²/s; methane permeability not more than 1.1·10⁻⁶ m³/(m²·h·atm); seismic resistance up to intensity 9 on the MSK-64 scale; resistance to mould fungi not more than 3 points (GOST 9.049-91); potential service life 100 years (NIISF RAASN); mass 2; 2.7 kg/m²
Layer thickness1.5 and 2.0 mm
Shelf life18 months; store rolls horizontally on a pallet, not more than 3 high, in the factory packaging, in a dry enclosed room or under a canopy
StandardsSTO 72746455-3.4.3-2015

Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.

Other materials by TECHNONICOL