Gidrobeton SRG-F1 — fibre-reinforced shrinkage-compensated repair mortar
Repair mix with polypropylene fibre and compensated shrinkage for concrete defects in interior and exterior work; bond 2.0 MPa.

The Ultraplat bentonite cord is laid in the construction joint before concreting: the flexible profile on a bentonite-rubber base swells when wetted and seals the joint. Swelling after 5 h is at least 200%, after 24 h at least 400%, and resistance to hydrostatic pressure is 7 atm. The cord is installed in a continuous loop on rubber adhesive or mesh, joined butt-to-butt or overlapped without welding; installation is possible from −15 to +50 °C, including during reconstruction of service penetrations.
| Manufacturer | Kalmatron — OOO “Kalmatron-SPb”, Saint Petersburg |
|---|---|
| Type | waterstops and swelling profiles |
| Use | joints and abutments, foundations and basements |
| Base | self-expanding flexible profile of rectangular cross-section on a bentonite-rubber base |
| Packaging | cardboard boxes of 40 linear m |
| Application method | for construction joints and service penetrations (new construction and repair); laid in a continuous loop with tight contact; fixing with rubber adhesive (wait 5–6 min, press for 2–3 min) or with PVC/metal mesh with a mesh size from 10 mm on nails or dowels; joined butt-to-butt or with a 0.1 m overlap, without welding; protect from water before concreting, on a damp substrate concrete no later than 12 h; when reconstructing penetrations — a chase at least 70 mm deep and at least 50 mm wide, stop leaks with Kalmastop, caulk with Kalmatron-Shovny |
| Application temperature | from −15 to +50 °C |
| Key properties | density at least 1.4 g/cm³; swelling after 5 h at least 200%, after 24 h at least 400%; watertightness — filtration coefficient max 2.0×10⁻⁹ m/day; flexibility on a bar R=25 mm at −40 °C — no cracks; tensile strength at break at least 0.4 MPa; relative elongation at break at least 200%; watertightness at a pressure of 0.35 MPa for at least 2 h; resistance to hydrostatic pressure 7 atm |
| Standards | TU 5775-001-54282519-2010; certificate of conformity ROSS RU.AZh33.N00388 (15.04.2019–14.04.2022); expert opinion 77.01.16.P.004917.05.13 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Repair mix with polypropylene fibre and compensated shrinkage for concrete defects in interior and exterior work; bond 2.0 MPa.
Fine-grained cementitious mix for repairing and waterproofing concrete by hand or by dry-mix shotcreting; watertightness at least 14 atmospheres.
Two-component cement-polymer waterproofing for foundations, pools and wet rooms; elongation at break at least 50%, W18.
Self-compacting cementitious mix for grouting equipment and steel structures, installing anchors and repair; 70 MPa compressive at 28 days.
Cementitious mix for repairing and waterproofing concrete, masonry, joints and screeds in tanks and treatment plants; compressive strength at least 50 MPa.
Rapid-hardening non-shrink mix for grouting columns, equipment and bridge bearings at air temperatures down to −10 °C.