UTECH HITRE 500 chemical bonded anchor — epoxy anchor for rebar and studs
Epoxy bonded anchor for M8–M36 studs and rebar in cracked and non-cracked concrete, including water-filled holes; installation from −10 °C.

The rapid-hardening acrylate anchor UTECH ICE 500 is designed for installation in frost: the substrate temperature may range from −25 to +25 °C, while the tube must be no colder than 0 °C. It is used to bond M8–M24 studs and rebar of 10–25 mm diameter into dry B25–B60 concrete, cracked and non-cracked, in floors, walls and ceilings; moisture is not permitted during installation and strength gain. At +20…+25 °C full strength gain takes 45 min, at −25…−11 °C 36 h; a technical certificate of the Ministry of Construction of Russia has been issued for the anchor.
| Manufacturer | UTECH — OOO “ASP-GRUPP”, Ivanteyevka |
|---|---|
| Type | chemical anchors |
| Use | anchoring of rebar and bolts |
| Base | two-component rapid-hardening acrylate-based adhesive compound (component A — bisphenol A ethoxylate dimethacrylate, 2-hydroxypropyl dimethacrylate, trimethylolpropane trimethacrylate; component B — 2-ethylhexyl benzoate, dibenzoyl peroxide) |
| Packaging | tube 300 ml; coaxial 10:1 dispensers or standard 300 ml sealant guns |
| Application method | bonding of threaded studs M8–M24 (hef from 60–160 mm for M8 to 96–480 mm for M24) and rebar Ø10–25 mm (hef up to 100–500 mm for Ø25) in a dry substrate of B25–B60 concrete, cracked and non-cracked, hammer drilling, installation in floors, walls and ceilings; installation in frost; prevent exposure to moisture during installation, hardening and strength gain; hole by hammer drilling (for HITRE 500 also by diamond drilling, with roughening), cleaning with a brush and blowing out; discard the first compound from a new mixer; fill the hole to about 2/3 from the bottom, insert the stud or rebar with a twisting motion; apply load after full strength gain; a started tube with the mixer screwed on can be used within 7 days (new mixer, discard the first compound again) |
| Application temperature | substrate −25…+25 °C; tube temperature during installation not below 0 °C |
| Curing | working time / full strength gain: +20…+25 °C — 3 min / 45 min; +10…+19 °C — 5 min / 1 h; +5…+9 °C — 45 min / 4 h; 0…+4 °C — 1.5 h / 8 h; −5…−1 °C — 2 h / 16 h; −10…−6 °C — 2 h / 24 h; −25…−11 °C — 3 h / 36 h |
| Key properties | characteristic bond strength to B25 concrete (hammer drilling, dry substrate): floor, non-cracked τn,urc 7.1 / 7.0 / 7.0 / 7.0 / 6.9 / 5.7 N/mm² (M8 / M10 / M12 / M16 / M20 / M24); walls and ceiling, non-cracked 6.7 / 6.6 / 6.5 / 6.5 / 6.5 / 5.4 N/mm²; cracked 2.0 N/mm² for all diameters; ψc from 1.00 (B25) to 1.09 (B60); service temperature (range I) −70…+42 °C, long-term up to +25 °C |
| Shelf life | 12 months from the date of manufacture; storage at +5…+25 °C in closed packaging, in dry heated premises, no closer than 1 m to heating appliances, do not freeze |
| Standards | STO 17523759-033-2025; certificate of conformity SDS “SMIK” No. RU.SMIK.001.N.00562 valid from 27.03.2026 to 26.03.2029; technical certificate of the Ministry of Construction of Russia No. 7425-26 dated 27.03.2026 (valid until 27.03.2028, HITRE 500 and ICE 500); state registration certificate; design per SP 513.1325800.2022 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Epoxy bonded anchor for M8–M36 studs and rebar in cracked and non-cracked concrete, including water-filled holes; installation from −10 °C.
Epoxy anchor for M8–M24 studs and rebar in dry concrete: fences, railings, gates, wall-mounted and building services equipment.
Non-shrink epoxy grout under columns, equipment and bridge structures under static and dynamic loads; 100 MPa in 7 days.