Wetisol Spray 400 — hot-spray polyurea
Sprayed polyurea for foundations, tanks, roofs and bridges: a seamless membrane with 350–450% elongation, working from −60 to +90 °C.

WETISOL Spray 250H is based on hybrid polycarbamides and is applied by hot spraying, without solvents or volatile organic compounds. The compound forms a membrane on concrete, stone, metal and non-rigid substrates and is used on foundations, in tanks and pools, on roofs, in tunnels, on bridges and dams. The hybrid grade has lower strength and elongation — at least 13.0 MPa and 150–250% — and spraying is permitted only from +10 °C. Gel forms in 10–15 s, and service is possible from −50 to +70 °C.
| Manufacturer | Wetisol (INGRI) — OOO “Ingri” |
|---|---|
| Type | polyurea |
| Use | foundations and basements, tanks and pools, roofs, tunnels and metro, bridge structures, hydraulic structures and dams |
| Base | two-component material based on hybrid polycarbamides for hot spray application; contains no volatile organic compounds or solvents |
| Colour | the unpigmented material is tinted with specialised pigment pastes at no more than 2% of the weight of comp. A; under UV exposure the colour gradually changes shade |
| Packaging | kit A+B 40 kg and 440 kg |
| Application method | protection and waterproofing of concrete, stone and metal structures, membrane on non-rigid substrates (bituminous roll materials, asphalt concrete, polyurethane foam); hot spraying with a two-component high-pressure reactor (e.g. ZOGEL ZS-7H240, ZS-12H240): feed hoses and components +70…+80 °C, preheating +30…+40 °C, pressure at least 150 bar (150–210 bar recommended), A:B = 1:1 by volume; homogenise the components before work (cans — mixer up to 500 rpm for 0.5–1.5 min, drums — drum tumbler or stirrer for 5–7 min); trial spraying on 1 m² with a cut-section check; concrete — abrasive treatment with vacuum dust removal, repair and priming with WETISOL S-CP (filler S-CP : quartz sand 1:1–2, then 1:3–4 by weight); metal — abrasive blast cleaning to degree 2 per GOST 9.402 / Sa 2½ per ISO 8501-1, Rz > 60 µm, salt and pH control, WETISOL S-MP1 or S-MP2 primer (application without primer is permitted after an adhesion test); tiles, stone — shot or sand blasting; non-rigid and bituminous substrates, asphalt concrete — WETISOL S-MP1 or SprayFoam-30/50; over WETISOL SprayFoam-30/50 rigid foam — without primer; spraying no later than 1–1.5 days after priming; substrate dense and even, without puddles or darkening from moisture, moisture max 5.0 wt. %; flushing of equipment with WETISOL Clean; to be applied by qualified specialists only |
| Application temperature | spraying of Spray-250H onto the prepared surface from +10 °C to +40 °C; primers: WETISOL S-CP +10…+30 °C, S-MP1 −10…+30 °C, S-MP2 −12…+50 °C; over SprayFoam-30/50 +10…+30 °C; substrate 3 °C above the dew point; relative air humidity max 80% |
| Curing | gelation 10–15 s; light load after 30 min; full cure after 7 days; next coat — immediately after the previous one, but no later than 48 h (at +20±2 °C, 60±5%) |
| Key properties | dynamic viscosity at +23 °C: comp. A 1,000–1,400 mPa·s, comp. B 600–1,300 mPa·s (GOST 25271); density of the cured composition 1.12±0.1 kg/dm³ (GOST 15139); Shore D hardness (7 days) at least 38 (GOST 24621); relative elongation at break 150–250% (GOST 11262); Taber abrasion resistance (CS10/1,000 g/1,000 rev) max 30 mg; tensile strength at break at least 13.0 MPa (GOST 11262); adhesion to concrete at least 2.5 MPa, failure in the concrete (GOST 28574); membrane watertightness (S=2 mm, 24 h) at least 2.0 kgf/cm² (GOST 2678); service temperature from −50 to +70 °C (short-term up to +80 °C) |
| Layer thickness | design membrane thickness 2.0 mm |
| Consumption | 2.2 kg/m² for a membrane with a design thickness of 2.0 mm (for reference); over SprayFoam rigid foam (20–25 mm, 1.0 kg/m²) — also 2.2 kg/m²; primers: S-CP 0.35 kg/m² (filler 0.50 kg/m² + sand 0.75 kg/m²), S-MP1 0.15 kg/m², S-MP2 0.40 kg/m² |
| Shelf life | 6 months from the date of manufacture in unopened original containers at +5…+25 °C; transport at −10…+35 °C for no more than 7 days |
| Standards | TU-5775-020-94613022-2014 with amendment No. 1 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Sprayed polyurea for foundations, tanks, roofs and bridges: a seamless membrane with 350–450% elongation, working from −60 to +90 °C.
Low-toxicity benzoate-based cleaner for flushing, lubricating and preserving spray rigs, and for pumps after injection resins.
Hot-spray polyurea for foundations, tanks, roofs and tunnels, also suitable for protective floor coatings; elongation 250–350%.
Polyurethane primer for polyurea and polyurethane coatings on metal, PVC roofs, bitumen and concrete; intermediate coat for LAM 361 mastic.
Two-component epoxy primer for concrete and brick under Wetisol Spray sprayed polyurea; adhesion to concrete over 4.0 MPa.
Cementitious coating waterproofing for tanks, pools and foundations without movement: W16 under positive and W8 under negative pressure, bond from 1.7 MPa.