AquaMast cold bituminous mastic for roof repair and waterproofing
TECHNONICOL

AquaMast cold bituminous mastic for roof repair and waterproofing

AquaMast repair mastic is packed in small 3 kg euro pails and designed for spot work on roofs: sealing blisters, cracks, tears and holes, and partial sealing of roll and mastic coverings. It is also used to bond bituminous materials to brick, plaster, concrete, metal, timber and ceramics. The mastic has a pot life of at least 2 h, withstands heating up to +100 °C and is applied by spatula or trowel at −10…+40 °C. It is not used inside residential premises.

Specifications

ManufacturerTECHNONICOL — OOO “Zavod Technoflex”, OOO “Zavod TechnoNICOL-Ulyanovsk”, Uchaly, Voskresensk, Novoulyanovsk
Typemastics and liquid membranes
Useroofs
Basehomogeneous mass of bitumen, filler, solvent and process additives
Packaging3 kg metal pails
Application methodrepair of roll and mastic roofing (blisters, cracks, tears, holes, partial sealing); bonding bituminous materials to brick, plaster, concrete, metal, timber, ceramics; substrate dry and clean, absorbent substrates — AquaMast bitumen primer; by spatula or trowel: defect repair — coat not more than 4 mm, bonding of rolls — not more than 1 mm; cut open blisters, coat and press down the edges, reinforce with glass mesh if necessary; on roofs with a slope of up to 5° roll the membrane into the mastic; do not use inside residential premises
Application temperaturefrom −10 to +40 °C; below +5 °C keep the mastic at room temperature for at least a day
Curingdrying approx. 1 mm per day as a stand-alone coating; when bonding roll materials, final drying takes up to 2–4 weeks
Key propertiesbond strength to concrete, metal, roll material to roll material and roll material to concrete at least 0.1 MPa; shear strength of the adhesive bond at least 0.1 kN/m; nominal tensile strength at least 0.2 MPa (GOST 26589-94); non-volatile content by mass 82–92% (GOST 31939-2022); heat resistance not lower than +100 °C; pot life at least 2 h; watertightness at a pressure of at least 0.001 MPa for 72 h — passes; flexibility temperature on a bar R = 5 mm not higher than +5 °C; combustibility group G4 (GOST 30244-94), ignitability V3 (GOST 30402-96), flame spread RP4 (GOST R 51032-97)
Layer thicknessdefect repair — not more than 4 mm; bonding of roll materials — not more than 1 mm
Consumption0.8–1.8 kg/m² depending on the type of work
Shelf life18 months from the date of manufacture; in a dry, ventilated room protected from the sun, with supply and exhaust ventilation, at −20…+30 °C, pallets in a single tier, following the rules for highly flammable materials
StandardsTU 5775-065-72746455-2012; GOST 30693-2000