PLAMCOR-5 fire-retardant paint for hydrocarbon fires (VMP)
Epoxy intumescent coating for steel structures at oil and gas facilities: hydrocarbon regime, fire resistance rating up to 120 minutes.

A gloss epoxy enamel on a polyamide hardener that forms a uniform decontaminable coating on metal and concrete. It is used at nuclear power plants and radiochemical plants — on walls, ceilings, floors, pipelines and equipment of the controlled access area, as well as on containers for nuclear waste; it meets GOST R 51102 for protective decontaminable polymer coatings. It withstands decontamination and process solutions of acids and alkalis, allows electrostatic spraying and is suitable for repairing EP-5285 and EP-1155D coatings.
| Manufacturer | VMP — AO “NPKh VMP”, Yekaterinburg |
|---|---|
| Type | epoxy enamels and coatings |
| Base | epoxy resin and polyamide hardener, two-pack |
| Colour | white, grey and others by agreement; uniform gloss |
| Packaging | kit: base and hardener in metal pails and metal cans |
| Application method | airless (nozzle 0.015–0.021″, 15–22 MPa) and air spray — 1–2 coats; electrostatic spraying with SOLVIN-16 thinner — 1–2 coats; roller, brush — 2–3 coats; base:hardener 100:5.8 by weight; thinners SOLV-EP, SOLVIN-12 max. 3 % (by weight) |
| Application temperature | from +5 to +35 °C, relative humidity max. 85 %; surface at least 3 °C above the dew point; temperature of the prepared enamel not below +15 °C; concrete — at least 28 days after placing, moisture of the surface layer max. 4 % |
| Drying | to degree 3 — no more than 16 h at 20 °C; drying between coats — at least 24 h at 20 °C |
| Key properties | density — 1.1–1.3 g/cm³, pot life at 20 °C — at least 8 h, volume solids — 50±2 %, non-volatile matter by weight — 63.5±1.5 %, resistance to decontamination solutions, process solutions of acids and alkalis; water- and weather-resistant |
| Compatible materials | stand-alone coating over metal and concrete; finish coat over VINIKOR-ecoprime, TSINEP primers, IZOLEP-mastic primer-enamel, EP-0010 putty; on galvanised steel — over VL-023 or AK-070 primer; repair of EP-5285 and EP-1155D coatings |
| Shelf life | base and hardener — 24 months from the date of manufacture |
| Standards | TU 20.30.12-017-67503963-2019; state registration certificate RU.77.01.34.008.E.003256.12.21; GOST R 51102 (protective decontaminable polymer coatings); conclusions of FSUE “NITI named after A.P. Aleksandrov”, AO “NIKIMT-Atomstroy” |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Epoxy intumescent coating for steel structures at oil and gas facilities: hydrocarbon regime, fire resistance rating up to 120 minutes.
Moisture-curing polyurethane enamel — an intermediate coat over zinc primers for bridges, steel structures and oil and gas, applied from −15 °C.
Epoxy intumescent compound for fire protection of steel structures in a cellulosic fire, including in the open industrial atmosphere.
Zinc-containing shop primer for automatic lines in steel fabrication and shipbuilding: interim protection up to 1 year, welding and cutting through the coating.
Epoxy primer with at least 89 % zinc for highly aggressive industrial environments, bridges, oil and gas and marine structures.
Moisture-curing zinc silicate primer for furnaces, boilers and heated pipelines, including those operating under thermal insulation.