TSVES-MO — zinc silicate primer for hot surfaces up to +400 °C
Moisture-curing zinc silicate primer for furnaces, boilers and heated pipelines, including those operating under thermal insulation.

For steel structures operating in any type of atmosphere, including the open industrial atmosphere, VMP produces PLAMCOR-302, a two-pack epoxy composition with an amine-type hardener designed for the cellulosic fire regime. The coating is weather-resistant and requires no reinforcement. Besides spraying and brushing, a trowel may be used, as well as heated units with separate feed of components approved by the manufacturer. The material is for professional use only; it holds an SDS INTERGAZCERT certificate and an MGSU conclusion on seismic resistance.
| Manufacturer | VMP — AO “NPKh VMP”, Yekaterinburg |
|---|---|
| Application | steel structures |
| Service conditions | macroclimatic regions U, UKhL, KhL, all atmosphere types and placement categories per GOST 15150, incl. open industrial atmosphere |
| Base | epoxy, two-pack, amine-type hardener; intumescent, for cellulosic fire |
| Colour | light grey (shade not standardised) |
| Packaging | base — 20 l metal bucket, hardener — 5 l |
| Application method | airless spray, trowel, brush; heated units with separate feed of components approved by the manufacturer are permitted |
| Application temperature | from −5 to +35 °C, relative humidity ≤ 80 % |
| Drying | to degree 3 — no more than 12 h; between coats — at least 24 h; before enamel — from 24 h to 1 month; full — at least 7 days (20 °C) |
| Compatible primers and topcoats | under intense UV — POLITON-UR (UV), VINIKOR-62, polyurethane, vinyl-epoxy; primers TSINEP, IZOLEP-primer, IZOLEP-mastic, VINIKOR-ecoprime |
| Shelf life | 12 months |
| Standards | TU 20.30.22-123-12288779-2020; GOST 15150; GOST 9980.5; GOST 19007; EAEU, NSOPB and SDS INTERGAZCERT certificates |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Moisture-curing zinc silicate primer for furnaces, boilers and heated pipelines, including those operating under thermal insulation.
Thixotropic epoxy primer for the internal surfaces of tanks, tank cars and pipelines, working in a system with NEFTEKOR enamel.
Epoxy syntactic foam — a thermal insulation layer of combined steel fire protection that works only together with intumescent PLAMCOR products.
Epoxy intumescent coating for steel structures at oil and gas facilities: hydrocarbon regime, fire resistance rating up to 120 minutes.
Gloss epoxy urethane coating with 90 % solids for metal and reinforced concrete in an industrial atmosphere without ultraviolet.
High-build epoxy coating for tanks and pipelines with crude oil, fuel oil and bottom water; predicted service life 20 years.