UTECH SP-EG epoxy grout — non-shrink grout under equipment
Non-shrink epoxy grout under columns, equipment and bridge structures under static and dynamic loads; 100 MPa in 7 days.

The epoxy anchor UTECH HITRE 100 is intended for everyday fixings — temporary structures, fences, railings, gates, grilles, wall-mounted equipment, air conditioning and lighting systems. It bonds M8–M24 threaded studs and rebar of 8–25 mm diameter into dry hammer-drilled holes in B25–B60 concrete, including cracked concrete, in compression and tension zones. Installation is carried out at substrate temperatures of +5…+40 °C, the connection works from −40 to +42 °C; the 585 ml tube is white or black.
| Manufacturer | UTECH — OOO “ASP-GRUPP”, Ivanteyevka |
|---|---|
| Type | chemical anchors |
| Use | anchoring of rebar and bolts |
| Base | two-component epoxy-based adhesive compound (component A — epoxy resin, 1,4-butanediol diglycidyl ether, 3-glycidoxypropyltrimethoxysilane; component B — 1,5-diamino-2-methylpentane, m-xylylenediamine, 3-aminopropyltriethoxysilane, quartz flour) |
| Colour | white or black tube |
| Packaging | tube 585 ml; two-component dispensers HDM / HDE with cartridge U-500 |
| Application method | bonding of threaded studs M8–M24 (hef from 60–160 mm for M8 to 96–480 mm for M24) and rebar Ø8–25 mm in a dry substrate of B25–B60 concrete, cracked and non-cracked, hammer-drilled holes; compression and tension zones of concrete; everyday fixings: temporary structures, fences, railings, gates, grilles, wall-mounted equipment, air conditioning and lighting; hole by hammer drilling (for HITRE 500 also by diamond drilling, with roughening), cleaning with a brush and blowing out; discard the first compound from a new mixer; fill the hole to about 2/3 from the bottom, insert the stud or rebar with a twisting motion; apply load after full strength gain; a started tube with the mixer screwed on can be used within 7 days (new mixer, discard the first compound again) |
| Application temperature | substrate +5…+40 °C; tube temperature during installation +5…+35 °C |
| Curing | working time / full strength gain: +5…+9 °C — 2.5 h / 24 h; +10…+14 °C — 2 h / 16 h; +15…+19 °C — 1.5 h / 12 h; +20…+24 °C — 1 h / 7 h; +25…+29 °C — 45 min / 6 h; +30…+34 °C — 30 min / 5 h; +35…+40 °C — 20 min / 4.5 h |
| Key properties | characteristic bond strength to B25 concrete (hammer drilling, floor, dry substrate): non-cracked τn,urc 13.2 / 13.2 / 13.2 / 13 / 13 / 12.7 N/mm² (M8 / M10 / M12 / M16 / M20 / M24), cracked τn,rc 3.6 / 3.6 / 3.6 / 3.5 / 3.4 / 3.3 N/mm²; factor for actual concrete strength ψc from 1.00 (B25) to 1.04 (B60); temperature range I −40…+42 °C (long-term up to +25 °C); tested for static and quasi-static loads |
| Shelf life | 12 months from the date of manufacture; storage at +5…+25 °C in closed packaging, in dry heated premises, no closer than 1 m to heating appliances, do not freeze |
| Standards | STO 17523759-032-2025; certificate of conformity SDS “SMIK” No. RU.SMIK.001.N.00560 valid from 27.03.2026 to 26.03.2029; state registration certificate; design per SP 513.1325800.2022 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Non-shrink epoxy grout under columns, equipment and bridge structures under static and dynamic loads; 100 MPa in 7 days.
Epoxy bonded anchor for M8–M36 studs and rebar in cracked and non-cracked concrete, including water-filled holes; installation from −10 °C.
Rapid-hardening acrylate anchor for M8–M24 studs and rebar in dry concrete at substrate temperatures down to −25 °C; 300 ml tube.