ALFAPOL VB ZIMA — concrete floor for laying at low temperatures
Industrial concrete floor that can be laid at −5…+10 °C, for workshops, warehouses, wet rooms and open areas.

A self-levelling version of the antistatic polyurethane-cement floor: the three components are mixed into a flowable mass and laid over the PU-1V AS conductive layer with copper earthing tape. Surface and volume resistance is no more than 10⁶ Ω, compressive strength 30 MPa, bond strength to concrete 2 MPa. At +20 °C the floor can be walked on after 3 days and fully loaded after 7 days; works are carried out at +15…+30 °C and substrate moisture up to 7%.
| Manufacturer | ALFAPOL — OOO “ALFAPOL”, Saint Petersburg |
|---|---|
| Type | polyurethane-cement floors |
| Use | production halls, warehouses and logistics, food and pharmaceutical, chemically resistant, antistatic/conductive, outdoor areas |
| Base | polyurethane-cement; Antistatic non-sparking self-levelling heat-resistant polyurethane-cement industrial floor |
| Colour | tinting to RAL with restrictions |
| Packaging | Component A: 5.4 kg, Component B: 5.9 kg, Component C: 19.9 kg (bag) |
| Application temperature | Application temperature, °C: +15°C to +30°C; Substrate moisture, max.: 7%; Air and substrate temperature: from +10 to +25°C |
| Curing | At 20 °C: foot traffic after 3 days, medium load after 5 days, full load after 7 days; Recoat interval, min., hours: 24 |
| Key properties | Surface electrical resistance (point-to-point), max., Ohm: 10^6; Volume electrical resistance (to ground point), max., Ohm: 10^6; Taber abrasion: 75; Compressive strength, MPa: 30; Bond strength to concrete (failure in concrete), min., MPa: 2 |
| Consumption | at 2.5 mm layer thickness – 4.9 kg/m² |
| Shelf life | Shelf life, months: 6 |
| Standards | TU 23.64.10-006-82166262-2018 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Industrial concrete floor that can be laid at −5…+10 °C, for workshops, warehouses, wet rooms and open areas.
Self-levelling antistatic polyurethane floor for production sites, food and pharmaceutical workshops, retail and public buildings.
Cement-based antistatic concrete floor with crushed marble for workshops, warehouses and outdoor areas where the coating must not spark or build up charge.
Heat-resistant polyurethane-cement render for coves, skirtings and protective layers on walls and foundations in PU-cement floor systems.
Versatile non-sparking "liquid topping" for hardening concrete, designed for significant mechanical impact.
Highly filled non-sparking polyurethane-cement floor for fire-hazardous production facilities, storage facilities and outdoor areas.