Elakor-MB1 Fluat — fluating impregnation for hardening concrete floors
Water-based fluating concentrate for hardening and dust-proofing concrete floors in warehouses, workshops, car parks and outdoor areas.

The primer is mandatory before laying the polyurethane-cement floors of the series and closes the pores of concrete and sand-concrete screeds of grade not lower than M350 in 1–2 coats. Substrate moisture, air humidity and dew point are not limited for it; the only requirement is the absence of puddles. According to the technical data sheet, the main layer is laid at +20 °C not earlier than 24 and not later than 36 hours afterwards; the coating itself is dark grey and semi-matt, fire hazard class KM2.
| Manufacturer | Elakor — OOO “TEOKHIM-PROM”, Moscow Region |
|---|---|
| Type | floor primers |
| Use | production workshops, warehouses and logistics, car parks and ramps, food and pharmaceutical |
| Base | polyurethane-cement three-component primer for “Elakor-PTs” systems |
| Colour | dark grey coating, semi-matt/matt finish |
| Packaging | Comp. “A” 8.7 kg + Comp. “B” 6.5 kg + Comp. “C” 14.5 kg = Kit 29.7 kg |
| Application method | Priming when installing polyurethane-cement coatings; stand-alone PTs coatings. Substrate: concrete, concrete and sand-concrete screeds not lower than M350 (B25), cured for at least 28 days; surface moisture is not limited (no puddles); relative air humidity and dew point are not limited. Flat trowels, rollers; 1-2 coats; pores closed, uniform layer. |
| Application temperature | air, surface: optimum +17…+23°C; permissible +10…+30°C; material temperature +18…+22°C |
| Curing | pot life on the surface at (20±2)°C at least 15 min; interval before the main PTs layer: at +10°C – at least 36 h, but not more than 48 h; at +20°C – at least 24 h, but not more than 36 h; at +30°C – at least 18 h, but not more than 24 h |
| Key properties | A:B:C ratio by weight 8.7 : 6.5 : 14.5; density 1.48±0.05 kg/l; adhesion (GOST 28574-2014) to concrete B25 > 2.5 MPa, to concrete B40 > 4.0 MPa (failure in concrete); Shore D hardness 80-85; impact strength U-2M 100 cm; Taber abrasion CS-10, 1000 g, 14 days, not more than 20 mg; service temperature -30°C…+70°C continuous, short-term for up to 2 h up to 150°C; fire hazard class KM2 (V2, D1, T1, RP1); chemical resistance: water, salt and alkali solutions of any concentration, acid solutions up to 10-20%, oils and fats of all kinds, organic solvents, petrol, diesel fuel |
| Consumption | 1-2 coats, total consumption 0.3-0.5 kg/m² (depends on surface porosity and roughness) |
| Shelf life | components “A” and “B” – 12 months, component “C” – 6 months in the manufacturer's original packaging; store and transport at temperatures from +5° to +25°C |
| Standards | Certificate of conformity (fire safety) “Elakor-PTs”, class KM2; Certificate of conformity “Elakor-PTs” |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Water-based fluating concentrate for hardening and dust-proofing concrete floors in warehouses, workshops, car parks and outdoor areas.
Two-component matt varnish with a gloss of 10–15 % for matting epoxy and polyurethane floors and sealing decorative coatings.
Two-component polyurethane sealant for thermal and movement joints in concrete floors, elongation at least 400 %.
Transparent lightfast polyurethane primer and concrete impregnation under Lyuks varnishes, including for outdoor areas.
Two-component epoxy primer with 92 % solids content for closing the pores of concrete under epoxy and polyurethane floors.
Two-component polyurethane electrically conductive primer for antistatic epoxy, polyurethane and polyurethane-cement floors.