GLIMS® PRO FS TOP 100 — quartz topping for concrete floors
Quartz hardening topping for floors under moderate and significant loads: warehouses, car parks, car service stations, production halls and retail areas.

Cure-A is used in two modes: it is sprayed under the blades of a power trowel when working with TOP 450 and TOP 100 toppings, or applied to already dry concrete by brush, roller or sprayer. The latex impregnation, free of organic solvents, prevents water evaporation, dustproofs the surface, increases its abrasion resistance and reduces absorption of oils and petroleum products. The compound must be stored and applied at +5…+35 °C and must not be frozen.
| Manufacturer | GLIMS — AO “GLIMS-Production”, Podolsk |
|---|---|
| Type | floor material |
| Use | warehouses and logistics, production halls, car parks and ramps, outdoor areas |
| Base | waterborne latex (acrylate) polymer curing impregnation, free of organic solvents |
| Colour | white |
| Packaging | plastic canister 10 kg |
| Application method | sprayed under the blades of a power trowel when working with TOP 450 / TOP 100 toppings (0.1–0.2 kg/m²) or impregnation of finished dry concrete by brush, roller, sprayer (0.1–0.3 kg/m²) |
| Application temperature | +5…+35 °C (substrate and air) |
| Key properties | density 1.05 g/cm³; service temperature −50…+70 °C; prevents water evaporation, dustproofs, increases abrasion resistance, reduces absorption of oils and petroleum products |
| Consumption | 0.1–0.3 kg/m² (with topping — 0.1–0.2 kg/m²) |
| Shelf life | 12 months; store at +5…+35 °C, protect from freezing and sunlight |
| Standards | TU 5775-007-40397319-2004 No. G-7010 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Quartz hardening topping for floors under moderate and significant loads: warehouses, car parks, car service stations, production halls and retail areas.
High-strength M400 cement screed for production halls, warehouses, car parks and car service stations, including unheated ones; walkable after 24 h.
Coarse-grained thixotropic R3 mortar for repairing concrete, steps and stair flights at temperatures from −15 to +15 °C; W12, F2 300.
Thin-layer non-shrink flowable R4 grout for anchoring in small gaps and hard-to-reach places; aggregate up to 0.5 mm, 60 MPa.
Fibre-reinforced flowable R4 mortar for repairing concrete under high humidity, loads and in aggressive environments; 60 MPa, W18, F2 400.
Thixotropic R2 mortar with fibre for filling voids, caulking joints, repairing manholes and tanks; compressive strength from 20 MPa at 28 days, W8.