TECHNONICOL No. 24 (MGTN) waterproofing mastic — bituminous, for foundations
Cold bituminous mastic for concrete, reinforced concrete and timber structures buried in the ground; applied at −20…+40 °C, not for roofs.

AquaMast polymer waterproofing based on an aqueous polymer dispersion is applied under ceramic tiles in wet rooms — bathrooms, WCs, laundries and on balconies. The grey solvent-free paste goes onto concrete, brick, gypsum, plaster, gypsum plasterboard, gypsum fibre board and KVL board, is suitable for underfloor heating and is applied by brush, roller or spatula in at least 2 coats. Elongation at break is at least 250%, adhesion to concrete is at least 1.5 MPa, and the watertightness class of concrete with the coating is W8. Tiles are laid on cementitious adhesive not earlier than after 12 h; the material is not used in pools or water tanks.
| Manufacturer | TECHNONICOL — OOO “Stroitelnaya Khimiya TECHNONICOL”, Ryazan |
|---|---|
| Type | mastics and liquid membranes |
| Use | interior spaces |
| Base | ready-to-use paste mastic based on an aqueous polymer dispersion, solvent-free |
| Colour | grey |
| Application method | on brick, concrete, gypsum, lime-cement and cement plaster, gypsum plasterboard (GKL), gypsum fibre board (GVL), KVL board; substrate sound, moisture content not more than 10%, free of laitance, cracks and cavities, smooth surfaces to be roughened; AquaMast deep-penetrating primer; at least 2 coats by brush, roller or spatula, the second across the first; junctions — TECHNONICOL MASTER acrylic sealant over the two coats or tape embedded in the first coat; tiles on cementitious adhesive C1/C2 (GOST R 56387-2018), do not use acrylic dispersion or solvent-based adhesives; do not use on roofs, as a wear-resistant coating or in tanks under constant hydraulic load (pools, wells, cooling towers, water tanks); dilution with water is permitted, use within 12 h |
| Application temperature | from +5 to +30 °C; substrate not below +5 °C; mastic not below +20 °C during application |
| Curing | intercoat drying at least 3 h (up to 4 h recommended); watertight after 8 h at +20 °C and 50% humidity; tiling after complete drying, not earlier than after 12 h |
| Key properties | density 1500 ±50 kg/m³ (GOST 31992.1-2012); non-volatile content by mass at least 70% (GOST 31939-2022); elongation at break at least 250% (GOST 26589-94); adhesion to concrete at least 1.5 MPa (GOST 32299-2025); heat resistance 5 h at +80 °C — passes; watertightness class of concrete with a 2 mm coat — W8 (GOST 12730.5-2018); crack resistance at least 2.5 mm (GOST 31383-2008); frost resistance 5 cycles at −30 °C — passes; not classified as dangerous goods |
| Layer thickness | not more than 0.5–0.6 mm per coat (0.8 kg/m²); 1.5 kg/m² = 1 mm of wet film or 0.7 mm of dry coating |
| Consumption | wet rooms 0.7–1.5 kg/m² in 2 coats; floors of dry residential rooms 0.4–0.7 kg/m²; showers and sauna floors 3 kg/m² in 4 coats (SP 29.13330.2011 cl. 7.4) |
| Shelf life | 18 months from the date of manufacture; store at +5…+35 °C; up to 5 freeze cycles down to −30 °C with gradual thawing are permitted |
| Standards | STO 72746455-3.6.30-2024; GOST 30693-2000 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Cold bituminous mastic for concrete, reinforced concrete and timber structures buried in the ground; applied at −20…+40 °C, not for roofs.
Ready-to-use cold bituminous mastic for coating waterproofing of foundations and piles made of concrete, metal and timber; water absorption max. 2% per day.
Cold bituminous mastic in a 3 kg pail for spot repair of roll and mastic roofs and for bonding bituminous materials to various substrates.
Solvent-free bitumen-polymer paste for foundations and floors inside residential premises; watertight after 8 h, can be diluted with water.
Hot mastic of bitumen and crumb rubber for protection of underground pipelines, roof joints and structures in the ground; four grades.
Internal PVC waterstop with a swelling profile for “slab — wall” and “floor slab — wall” cold joints; two-level protection against water.