Vetonit remokor LF-60 — pourable class R4 mortar with steel fibre
Vetonit

Vetonit remokor LF-60 — pourable class R4 mortar with steel fibre

With polymer and steel fibre, Vetonit remokor LF-60 is designed for structures under static and impact-dynamic loads: columns and beams, bridge slabs, dams, retaining walls, silos, cooling towers, airfield and road pavements, industrial floors. The non-shrink, non-segregating, high-flow class R4 mix is poured into formwork and allows elements with rebar corrosion of up to 15 % to be repaired without installing additional reinforcement. The flexural strength is at least 10 MPa at 28 days, the compressive strength 60 MPa, water impermeability W16.

Specifications

ManufacturerVetonit — OOO “Saint-Gobain Stroitelnaya Produktsiya Rus”, Arzamas
Typepourable repair mortars
Usecolumns and beams, bridges and overpasses, hydraulic structures and dams, roads and airfields, industrial buildings, floors
Basedry mix based on high-strength cements, graded sand and special additives with polymer and steel fibre; non-shrink, non-segregating, high-flow compound
Colourgrey
Packagingthree-ply paper bag with a polyethylene middle ply, 25 kg
Application methodclean the concrete, remove weak areas (grinding, milling, sandblasting, wet abrasive blasting, shot blasting), wash with pressurised water; clean the rebar and immediately coat it with “Vetonit remokor 05”; dampen the substrate 24 h beforehand and again before the work (matt-damp); water +10…+30 °C, mortar temperature +10…+20 °C; first the minimum amount of water, then the dry mix, mix for 3–5 min with a drill and low-speed paddle or in a concrete mixer, pause 5 min, remix, add the rest of the water if necessary; do not overdose water; pour into strong, watertight formwork soaked with water; pour from one side of the formwork (the pouring side higher and wider), the mix flows under its own weight; for a layer thicker than recommended add washed gravel (crushed stone) 5–10 mm (5–20 mm) in an amount of 50–60 % of the dry mix weight; when pouring 60 mm at a time — a stiffer mix; pour from one side so as not to trap air
Application temperature+5…+35 °C (air and substrate)
Curingkeep moist, protect from precipitation, sun and wind for 5 days; a film-forming curing compound may be used; for 5 days after the work the air and substrate temperature must not be below +5 °C
Key propertiesclass R4; maximum aggregate size 3 mm; water demand 3.0–3.3 l per 25 kg (12–13 %); working time 30 min; compressive strength at least 30 MPa (1 day), 40 MPa (7 days), 60 MPa (28 days) (actual 44.5 / 74.0 / 94.2); flexural tensile strength at least 5 MPa (1 day), 10 MPa (28 days) (actual 7.8 / 12.7); compressive modulus of elasticity at least 20 GPa (actual 37.3); bond strength to the substrate at least 2 MPa (actual 3.0); after restrained shrinkage 2.7 MPa, after restrained expansion 2.7 MPa; frost resistance grade at least F₁1000 / F₂300; water impermeability at least W16 (actual W20); chloride ions no more than 0.1 %; carbonation resistance no more than 2.07×10⁻⁴ cm2/s (actual 1.6×10⁻⁷); chloride ion penetration resistance (0–2 mm, 28 days) no more than 0.05 N/mm2; combustibility group NG; repair with rebar corrosion of up to 15 % without installing additional reinforcement
Shelf life12 months from the date of manufacture in factory packaging in a dry room at relative humidity no more than 60 %
StandardsSTO 56846022-004-2024 “Dry repair mixes”; GOST R 56378-2015 (declaration); declaration of conformity ROSS RU D-RU.RA01.V.40648/26; certificate of conformity to fire safety requirements RU C-RU.PB37.V.01230/24; SGR RU.77.01.34.008.E.000426.02.25

Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.