LEVELINE FP890 one-component polyurethane sealer — curing fresh concrete
Clear polyurethane sealer for curing freshly laid concrete and toppings in workshops and warehouses; dries in 2 hours at +20 °C.

The compound based on polyurethane-acrylic resin and water, solvent-free, is sprayed or rolled onto concrete and topping 1–2 hours after floating or immediately after grinding. The film reduces water evaporation, so the surface gains strength and wear resistance; it should not be covered with plastic sheeting. Besides floors, FK891 is used on road pavements and engineering structures. It keeps for 24 months and withstands 5 freeze-thaw cycles.
| Manufacturer | INDASTRO — OOO “Sedrus” |
|---|---|
| Type | impregnations and concrete hardeners |
| Use | production workshops, warehouses and logistics, outdoor areas |
| Base | polyurethane-acrylic resin, water; solvent-free |
| Colour | homogeneous white liquid |
| Packaging | plastic canisters 10 kg |
| Application method | sprayer, roller (12-16 mm pile), brush, squeegee; 1-2 h after floating the topping/concrete or immediately after grinding; 1-2 coats; do not cover with plastic sheeting |
| Application temperature | +10…+35 °C (substrate and application); air humidity no more than 80% |
| Curing | drying to degree 3 at +20 °C no more than 3 h |
| Key properties | Non-volatile content at least 35%; density 0.95-1.0 g/cm3; viscosity 18 ± 2 s (VZ-246, 4 mm nozzle); reduces water evaporation, increases strength and wear resistance |
| Consumption | 100-150 g/m2 for toppings and floated surfaces; up to 200 g/m2 for porous concrete (below M200) |
| Shelf life | 24 months; storage +5…+25 °C; withstands 5 freeze-thaw cycles |
| Standards | manufacturer's TU |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Clear polyurethane sealer for curing freshly laid concrete and toppings in workshops and warehouses; dries in 2 hours at +20 °C.
Thixotropic R4 repair mortar for structures made of B60 concrete and above; compressive strength at 28 days at least 80 MPa, flexural strength 10 MPa.
Non-shrink thixotropic R4 mortar to EN 1504 with polymer fibre: 20 MPa in compression after 2 hours, work at temperatures from −10 to +35 °C.
Two-component chemically resistant epoxy primer on concrete under lining and Khimskrin SE 2k coating; pot life at 20 °C at least 60 minutes.
Two-component low-viscosity epoxy resin for elastic bonding of structures with crack widths of 0.3–5 mm; elongation at break 30 %.
Cementitious grout for installing presses, machine tools, pumps and compressors, grouting under columns and repair by pouring; 60 MPa at 28 days.