TSINOL — one-component cold galvanising compound
Cold galvanising compound for steel structures, bridges and the power industry: 96 % zinc in the dry coating, applied down to −25 °C.

The main feature of EVOPOL-12 is application at air temperatures down to −25 °C: at +20 °C the coat dries to degree 3 in no more than 1 h, at −25 °C in 2 h. The material is one-pack, based on a modified acrylate, UV-resistant and tinted to RAL; it is applied directly to metal and concrete (DTM). It is used for steel structures, bridges, marine and port structures, and as part of a system also for areas with a heavily polluted industrial atmosphere. The coating withstands temperatures from −60 to +150 °C.
| Manufacturer | VMP — AO “NPKh VMP”, Yekaterinburg |
|---|---|
| Type | primer-enamels |
| Use | steel structures, concrete, bridges, marine and port structures |
| Base | modified acrylate, one-pack; direct-to-metal (DTM), UV-resistant |
| Colour | to the RAL catalogue, matt |
| Packaging | metal pails 20 l |
| Application method | airless spray (nozzle 0.015–0.019″, 12–16 MPa), air spray, brush, roller; thinner SOLV-UR or SOLVIN-11 up to 10 % by weight (brush/roller 5–10 %), at −25…+10 °C — toluene |
| Application temperature | air from −25 to +35 °C, relative humidity max. 85 %; surface at least 3 °C above the dew point, without visible moisture |
| Drying | to degree 3 — no more than 1 h at +20 °C, no more than 2 h at −25 °C |
| Key properties | coating resistance to temperatures from −60 to +150 °C, volume solids — 47±2 %, non-volatile matter by weight — 61±3 %, density — 1.3±0.1 g/cm³ |
| Compatible materials | stand-alone coating; finish over epoxy and polyurethane based primers, vinyl-epoxy, acrylic and other primers |
| Shelf life | 24 months from the date of manufacture |
| Standards | TU 20.30.12-126-12288779-2020; STO-01393674-008-2024 (TsNIITS); approved by IPKhiS Frishberg |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Cold galvanising compound for steel structures, bridges and the power industry: 96 % zinc in the dry coating, applied down to −25 °C.
Epoxy primer for steel, aluminium, fibreglass and concrete in chemical plants and shipbuilding; applied down to −10 °C.
Silicone primer-enamel for structures at oil and gas, chemical and power facilities heated up to +600 °C; over steel, concrete, brick.
Alkyd primer-enamel with low flame spread for escape routes and ship spaces; over metal and wood, RAL colours.
One-pack syntactic foam on acrylic and chlorinated resins — a thermal insulation layer under PLAMCOR-2 for steel indoors.
Moisture-curing zinc-rich primer for steel structures, bridges and marine structures, applied at air temperatures from −15 °C.