Elcon Zintech 96 cold galvanising compound — 96 % zinc in the dry film
One-component cold galvanising compound for bridges, power line towers, oil and gas and port structures; applied in frost down to −20 °C.

KO-85 varnish is a colourless silicone material on modified resin with a styrene-acrylic copolymer, manufactured to GOST 11066-74 and TU 2312-011-49222195-2013. It protects metal, concrete, brick, reinforced concrete and asbestos cement when heated up to +250 °C; on concrete and plaster it is applied in three coats, and dipping is permitted. In addition, the varnish serves as the base of KO-814 enamel (with aluminium powder 100 : 5) and as a modifying additive for acrylic and alkyd paints and coatings.
| Manufacturer | Elcon — OOO “Elcon”, Novocheboksarsk |
|---|---|
| Type | heat-resistant coatings |
| Use | steel structures, concrete |
| Base | silicone varnish: modified silicone resin with a solution of styrene-acrylic copolymer; aromatic solvents |
| Colour | colourless |
| Packaging | 20 kg |
| Application method | air or airless spray, roller, brush, dipping (working viscosity 12–17 s); 2–3 cross coats with drying to “tack-free” 0.5–2 h; preparation St 3 or Sa 2–Sa 2.5, degreasing; concrete and plaster — in three coats |
| Application temperature | from −30 °C to +40 °C; relative air humidity not more than 80 % |
| Drying | to degree 3 — 3 h at (20±2) °C; final drying at least 24 h; full cure on heating; installation — not earlier than 3 days |
| Key properties | Heat resistance: from −60 °C to +250 °C, Non-volatile matter by weight: 15–17 % (GOST), 15–18 % (TU), Conventional viscosity (VZ-246, 4 mm nozzle): 12–17 s (GOST), 11–17 s (TU) |
| Compatible materials | base for KO-814 enamel (KO-85 varnish + aluminium powder 100 : 5); modifying additive for acrylic and alkyd paints and coatings |
| Shelf life | 36 months from the date of manufacture; storage from −40 °C to +40 °C |
| Standards | GOST 11066-74; TU 2312-011-49222195-2013 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
One-component cold galvanising compound for bridges, power line towers, oil and gas and port structures; applied in frost down to −20 °C.
One-component primer-enamel for steel structures and equipment, applied over tightly adherent rust at temperatures down to −20 °C.
Silver barrier enamel with flake aluminium for steel structures and equipment; topcoat over Elcon Zintech zinc primer.
Two-component epoxy primer-enamel for steel structures, tanks, bridges and ports; applied down to −10 °C, 20-year service life with Elcon PU.
One-component polyorganosiloxane enamel for steel structures, pipelines and power equipment; the black version withstands up to +1,200 °C.
Fast-drying zinc-rich primer for steel structures, bridges, oil and gas and power equipment; applied down to −15 °C.