OGNEZA-PM-K cable penetration
Split steel cable penetration with an intumescent insert for single cables and bundles through walls and floors; IET 180.

OGNEZA-LAK-OD varnish suits several substrates at once: wood, plywood, chipboard, fibreboard, brick, concrete and plaster. It is a one-component acrylic product on a mixture of organic solvents; the coating belongs to class KM2 (G1, D2, T2) and is permitted on escape routes, inside and outside buildings. Shades range from clear to dark brown, with gloss and matt versions. The varnish is applied on its own or over fire-protective compounds, work is possible from −25 °C; the declared service life of the coating is at least 20 years.
| Manufacturer | OGNEZA — OOO “OGNEZA”, St Petersburg |
|---|---|
| Fire protection performance | G1, D2, T2; ignitability V1 / V2; KM2 |
| Application | timber, concrete and reinforced concrete |
| Service conditions | inside and outside buildings; service temperature from −40 to +60 °C; escape routes |
| Base | acrylic, on a mixture of organic solvents; one-component |
| Colour | clear to dark brown; gloss and matt |
| Packaging | 1 l, 2.4 l, 20 l |
| Application method | air spray gun, brush, roller, flow coating; thinning with R-4 ≤ 5 % |
| Application temperature | from −25 to +40 °C, relative humidity up to 90 % (per description) |
| Drying | coating formation — 7 days |
| Compatible primers and topcoats | used on its own or over fire-protective compounds |
| Shelf life | 12 months |
| Standards | TU 2313-005-92450604-2013; GOST 30244; GOST 30402; GOST 12.1.044; GOST 20811-75; state registration certificate |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Split steel cable penetration with an intumescent insert for single cables and bundles through walls and floors; IET 180.
Non-intumescent thermal insulation layer of the OGNEZA-KONSTRUKTIV system for steel structures; paired with OGNEZA-UM — 90 and 120 minutes.
Clear water-soluble impregnation for timber without decorative finish — rafters, roofs, scaffolding; groups I and II per GOST R 53292.
Split steel collar with an intumescent insert for plastic pipes in walls and floors; EI 180, up to EI 240 according to the manufacturer.
Self-adhesive intumescent tape for fire doors, hatches, dampers and air duct flanges; up to EI 240 as part of an assembly.
Telescopic fire collar for 125–240 mm ventilation ducts in walls with an additional partition and an air gap; EI 180.