Supply across Uzbekistan and to Kyrgyzstan, Tajikistan and Turkmenistan +998 93 815 00 53 Telegram sale@coatix.uz
Elakor-PU Antistatic Self-levelling Floor AST-7 — polyurethane antistatic floor
ELAKOR

Elakor-PU Antistatic Self-levelling Floor AST-7 — polyurethane antistatic floor

This polyurethane antistatic compound gives a coating with an elongation at break of 25 % and Shore D hardness of 55–60. It is suitable for static-dissipative and conductive floors under SP 29.13330.2011: the “surface – earthing system” resistance is not more than 10⁷ Ω, and the coating is spark-safe. It is poured over concrete of grade not lower than M200 primed with antistatic primer in electronics production, server rooms, operating theatres, laboratories and cleanrooms; compressive strength is 42 MPa.

Specifications

ManufacturerElakor — OOO “TEOKHIM-PROM”, Moscow Region
Typepolyurethane floors
Useproduction workshops, warehouses and logistics, retail and public premises, chemically resistant, antistatic/conductive
Basetwo-component polyurethane material; urethane prepolymers, hardener, functional additives, pigments
Colourcoloured (pigmented)
Packaging“A” + “B” = kit 19.2 kg + 4.8 kg = 24 kg
Application methodAntistatic self-levelling floors on concrete, sand concrete, terrazzo, concrete tile, cement self-levelling floors, stone, brick. Concrete not lower than M200, cured for at least 28 days, moisture not more than 4 wt%, evenness not more than 4 mm under a 2 m straightedge, slope not more than 0.5%; surface levelled, pores closed, primed with antistatic primer. Spreading with a squeegee rake with a notched blade or a notched trowel, rolling with a spiked roller. Relative air humidity not more than 80%; surface 3°C above the dew point.
Application temperaturesurface and air: from +5 to +22°C; material temperature: from +15 to +20°C
Curingpot life at (20±2)°C at least 30 min; drying to degree 3 at (20±2)°C not more than 10 h; working time of the material on the surface not more than 30 minutes
Key propertiesA:B ratio by weight 4:1; solids content at least 95%; density 1.33 kg/l; service temperature -60°C ... +80°C, short-term (up to 30 min) up to +140°C; compressive strength 42 MPa (GOST 4651-2014, ISO 604:2002); film tensile strength at least 14 MPa; elongation 25%; impact strength (U-2M) 100 cm; flexibility not more than 2 mm; Shore D at 28 days 55-60; Taber abrasion SC-10, 1000 g, 28 days – 19 mg; gloss at 60° 87-90%; conventional lightfastness at least 100 h; electrical resistance “earthing system – surface” with an antistatic layer thickness of not more than 1.5 mm not more than 10^7 Ω; fire hazard class KM2; chemical resistance: water, salt and alkali solutions of any concentration, acid solutions up to 10-20%, oils and fats of all kinds, organic solvents, petrol, diesel fuel
Layer thicknessthe resistance is specified for an antistatic self-levelling layer thickness of not more than 1.5 mm
Consumption1.4 kg (A+B) per 1 m² at a layer thickness of 1 mm
Shelf life8 months in the manufacturer's original packaging; store and transport at temperatures from +5° to +25°C
StandardsCertificate of conformity (fire safety) “Elakor-PU 2K”; Antistatic properties test; ROSTEST letter “Elakor-PU 2K”; MOSGOSEKSPERTIZA letter on the use of “Elakor-PU 2K” at garage facilities

Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.