OGNEZA-VD-D fire-retardant paint for timber
Water-based intumescent paint for timber structures inside buildings — rafters, attics, mansards; fire protection performance group I and II.

OGNEZA-LAK-OD varnish suits several substrates at once: wood, plywood, chipboard, fibreboard, brick, concrete and plaster. It is a one-component acrylic product on a mixture of organic solvents; the coating belongs to class KM2 (G1, D2, T2) and is permitted on escape routes, inside and outside buildings. Shades range from clear to dark brown, with gloss and matt versions. The varnish is applied on its own or over fire-protective compounds, work is possible from −25 °C; the declared service life of the coating is at least 20 years.
| Manufacturer | OGNEZA — OOO “OGNEZA”, St Petersburg |
|---|---|
| Fire protection performance | G1, D2, T2; ignitability V1 / V2; KM2 |
| Application | timber, concrete and reinforced concrete |
| Service conditions | inside and outside buildings; service temperature from −40 to +60 °C; escape routes |
| Base | acrylic, on a mixture of organic solvents; one-component |
| Colour | clear to dark brown; gloss and matt |
| Packaging | 1 l, 2.4 l, 20 l |
| Application method | air spray gun, brush, roller, flow coating; thinning with R-4 ≤ 5 % |
| Application temperature | from −25 to +40 °C, relative humidity up to 90 % (per description) |
| Drying | coating formation — 7 days |
| Compatible primers and topcoats | used on its own or over fire-protective compounds |
| Shelf life | 12 months |
| Standards | TU 2313-005-92450604-2013; GOST 30244; GOST 30402; GOST 12.1.044; GOST 20811-75; state registration certificate |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Water-based intumescent paint for timber structures inside buildings — rafters, attics, mansards; fire protection performance group I and II.
Self-adhesive intumescent tape for fire doors, hatches, dampers and air duct flanges; up to EI 240 as part of an assembly.
Solvent-borne fire-retardant paint for timber and concrete indoors and on facades; fire protection performance groups I and II, class KM1.
Self-priming fire-retardant varnish for timber, including parquet and facades: groups I and II, G1, V1, D2, T2, RP1, UV resistance.
Modular cable penetration with a removable cover: cables are added and removed without dismantling; for walls and floors, including gypsum fibre board walls.
Telescopic fire collar for 125–240 mm ventilation ducts in walls with an additional partition and an air gap; EI 180.