TECHNONICOL Mastic No. 33 — water-emulsion bitumen-latex, for spraying
TECHNONICOL

TECHNONICOL Mastic No. 33 — water-emulsion bitumen-latex, for spraying

Mastic No. 33 is applied with a two-channel metering unit: the latex-modified bitumen emulsion and the calcium chloride solution are fed separately, after which the coating sets within 1 min. The composition contains no solvents, the coagulant is included in the delivery, and the material can be applied to concrete with a moisture content of up to 10%. The mastic protects foundations, basements, bridges, tunnels and piles, pool floors, balconies and non-potable water tanks, and is also suitable for seamless roofs. Elongation is at least 1200%, watertightness is 0.3 MPa for 24 h, and heat resistance is not lower than +140 °C.

Specifications

ManufacturerTECHNONICOL — OOO “Zavod Technoflex”, Voskresensk
Typemastics and liquid membranes
Usefoundations and basements, bridge structures, tunnels and metro, interior spaces, tanks and pools, roofs
Basewater-emulsion bitumen mastic modified with latex and polymer modifiers, free of organic solvents; component A — mastic, component V — coagulant (hydrated calcium chloride to GOST 450-77, included in the delivery)
Packaging200 kg metal drums; component V (calcium chloride) included in the delivery
Application methodmechanised application with a two-channel metering unit (RX-27/28 or equivalent): waterproofing and anti-corrosion protection of foundations, basements, bridges, tunnels, overpasses, piles; seamless roofs; stir; substrate cleaned, concrete with a moisture content of up to 10% by mass is permitted; priming — component A without coagulant or TECHNONICOL primer No. 04 (0.15–0.25 kg/m²); solution V is prepared on site, 1 kg per 10 l of water; feed ratio of solution V to the mastic 1/8–1/10; do not mix components A and V (irreversible precipitation); spray in different directions in sections of 1–1.5 m with a 20 cm overlap; second coat after the first has dried completely; reinforcement with alkali-resistant materials
Application temperaturefrom +5 to +35 °C
Curingsetting and water release within 1 min; surface drying after 1–4 h; final development of properties 3–7 days depending on thickness; 4–6 h before the second coat at a consumption of 1.5 kg/m² per coat
Key propertiesbond strength to concrete at least 0.6 MPa, to metal at least 0.5 MPa; nominal tensile strength at least 0.7 MPa; elongation at least 1200% (GOST 26589-94); binder-plus-emulsifier content 53–65% (GOST R 58952.5); heat resistance for 4 h at least +140 °C; softening point at least +270 °C (GOST 26589-94 cl. 3.15); flexibility on a bar R = 5 mm at −35 °C — no cracks; watertightness for 24 h at a pressure of 0.3 MPa — passes (GOST 2678-94); combustibility group G4 (GOST 30244-94), ignitability V3 (GOST 30402-96), flame spread RP4 (GOST R 51032-97); not classified as dangerous goods
Layer thicknesswaterproofing 2 mm thick
Consumptionmastic roof 3.5–5.0 kg/m²; waterproofing 2 mm thick 3.0–3.5 kg/m²; priming with primer No. 04 0.15–0.25 kg/m²
Shelf life6 months from the date of manufacture; store in a place protected from the sun at +5…+30 °C, pallets in a single tier
StandardsSTO 72746455-3.6.31-2023; GOST 30693-2000

Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.