TRIOFLAME 8800 — weather-resistant fire protection compound
Two-component weather-resistant fire protection compound for steel structures: up to R150, service from −60 to +70 °C.

For work in cold weather, the TRIOFLAME range includes AK 7700: this compound based on styrene-acrylic resins and an organic solvent is applied at temperatures from −10 °C. Fire protection performance for steel structures is up to R150 in a cellulosic fire. Without a finish enamel, the coating is used inside heated premises without condensation (C1–C2 to ISO 12944-2), including food production facilities; the service range is from −40 to +70 °C. It is supplied in a 20 kg euro pail; the shelf life is 24 months.
| Manufacturer | TRIOFLAME (O3) — OOO O3-Coatings, Rostov Region |
|---|---|
| Fire protection performance | up to R150 (150 min), cellulosic fire |
| Application | steel structures |
| Service conditions | service from −40 to +70 °C; without enamel — inside heated premises without condensation (C1–C2 to ISO 12944-2); including the food industry |
| Base | single-component intumescent compound based on styrene-acrylic resins and an organic solvent; solids content 74.5±5% by volume |
| Colour | white |
| Packaging | euro pail 20 kg |
| Application method | airless spray (nozzle .019–.025"), manual application |
| Application temperature | −10…+30 °C; humidity not above 85% |
| Compatible primers and topcoats | primer TRIOCOR PRIMER 1100 / TRIOCOR MASTIC 4500; enamel TRIOCOR FINISH 5500 or others — according to fire safety certificates; cleaning — TRIOSOLV 0003 |
| Shelf life | 24 months; storage at −35…+35 °C |
| Standards | TU 20.30.12-002-40141638-2025 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Two-component weather-resistant fire protection compound for steel structures: up to R150, service from −60 to +70 °C.
Vermiculite-based fire protection plaster mix for steel: from R15 to R240 under standard and hydrocarbon fire regimes.
Two-component epoxy thermal insulation for steel structures: protection against cryogenic spills, a layer in combined fire protection systems.
Water-based acrylic intumescent paint for steel structures: up to R120 in a cellulosic fire, application at +5…+30 °C.
Single-component water-based acrylic thermal insulation material for facades, concrete and steel; weather-resistant, from −40 to +70 °C.
Two-component intumescent epoxy coating for steel: up to R120 in standard and hydrocarbon fires, service from −60 °C.