CarbonWrap® Repair ST repair mortar — thixotropic mix with fibre
Thixotropic fibre-reinforced cement mix for restoring spalls, potholes and cracks in concrete, including under CarbonWrap Grid.
The CarbonWrap Anchor rope is not a chemical anchor for rebar but an element of the composite system: it fixes CarbonWrap carbon tapes, fabrics and grids to masonry, concrete and reinforced concrete structures without temporary fixtures. The knitted rope of high-strength carbon fibres is produced in diameters of 10 mm (D10) and 12 mm (D12) in coils of 10 or 100 m and works together with the epoxy adhesives and saturating resins of the system. The ultimate tensile strength is at least 3.7 GPa, the modulus of elasticity at least 230 GPa.
| Manufacturer | CarbonWrap — OOO “Nanotekhnologicheskiy tsentr kompozitov”, Moscow |
|---|---|
| Type | composite strengthening |
| Base | anchor rope of high-strength carbon fibres, knitted construction, fibre direction 0° |
| Packaging | diameter 10 mm (Anchor D10) or 12 mm (Anchor D12); coils of 10 m or 100 m |
| Application method | used within the CarbonWrap external reinforcement system with carbon tapes, fabrics, grids and epoxy adhesives and saturating resins; fixes tapes, fabrics and grids without temporary fixtures; for masonry, concrete and reinforced concrete structures |
| Key properties | diameter 10 or 12 mm; ultimate tensile strength (calculated on the fibre in a microplastic specimen) at least 3.7 GPa; tensile modulus of elasticity (calculated on the fibre in a microplastic specimen) at least 230 GPa |
| Shelf life | 24 months from the date of manufacture; relative humidity no more than 85 % |
| Standards | TU 23.99.14-045-38276489-2017 (TU 1916-045-38276489-2017) |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Thixotropic fibre-reinforced cement mix for restoring spalls, potholes and cracks in concrete, including under CarbonWrap Grid.
Epoxy saturating resin for installing the CarbonWrap system on damp concrete, stone and metal, and under water; bond to concrete at least 2.5 MPa.
Epoxy primer for treating concrete, reinforced concrete and masonry before installing the CarbonWrap system; pot life at least 90 min.
CFRP laminate with an epoxy matrix for strengthening beams, bridges and industrial buildings; width 50 or 100 mm, strength above 3500 MPa.
Unidirectional carbon tape on 24K yarn for strengthening slabs, bridge span beams, columns and pylons; width 150, 300 or 600 mm.
Polyurethane-pultruded CFRP laminate 83 or 120 mm wide for strengthening beams, bridges and industrial structures; rolls of 11 linear m.