REKS® Litoy 110 — 110 MPa installation grout for wind turbine towers and equipment
High-strength rapid-hardening Portland cement grout with shrinkage compensators for wind turbines, bridges and equipment; 110 MPa at 28 days.

When repairs cannot be drawn out, REKS® Strukto BS 3 is used — a rapid-setting, rapid-hardening fibre-reinforced mortar of thixotropic type that can be worked at temperatures down to −10 °C. It restores vertical and overhead elements of concrete and reinforced concrete structures without formwork, beams and columns, including prestressed ones, and structures in a marine environment and under repeated loading. Compressive strength is at least 20 MPa after 2 hours, 30 MPa after 4 hours and 40 MPa after one day; class R4 per GOST R 56378, W18.
| Manufacturer | REKS — OOO “SPS” |
|---|---|
| Type | thixotropic repair mortars |
| Use | bridges and overpasses, tunnels and metro, hydraulic structures and dams, industrial buildings, tanks and treatment plants, columns and beams |
| Base | rapid-setting, rapid-hardening, high-strength fibre-reinforced cementitious repair mortar of thixotropic type that can be applied at a temperature of −10 °C |
| Colour | grey |
| Packaging | bag 25 kg |
| Application method | repair of damaged vertical and overhead elements of concrete and reinforced concrete structures without formwork; repair of structures in service in a marine environment; repair of structural elements subject to repeated loading |
| Application temperature | −10…+5 °C and above (at −10 °C layer 20–100 mm, at +5 °C — 10–60 mm) |
| Curing | when working above +5 °C — water spraying and covering for 24 h after the initial set |
| Key properties | compressive strength at 4 hours: ≥30 MPa; modulus of elasticity: ≥25,000 MPa; density of hardened mortar: 2.3 ± 5 % t/m³; freeze-thaw resistance: F2 300; bond to substrate at 28 days: ≥2.5 MPa; water impermeability: W18; compressive strength at 28 days: ≥60 MPa; flexural strength at 1 day: ≥5 MPa; flexural strength at 28 days: ≥8 MPa; bond to substrate at 28 days after 50 freeze-thaw cycles in salts: ≥2.0 MPa; aggregate size: 2.5 mm; flowability (truncated cone spread on a flow table): 125–135 mm; compressive strength at 2 hours: ≥20 MPa; flowability retention: ≥10 minutes; compressive strength at 1 day: ≥40 MPa; flexural strength at 2 hours: ≥3 MPa; capillary water absorption: no more than 0.4 kg/(m²·min⁰·⁵); flexural strength at 4 hours: ≥4 MPa; sulphate resistance coefficient (365 days): 0.982 % |
| Shelf life | 12 months from the date of manufacture |
| Standards | class R4 per GOST R 56378 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
High-strength rapid-hardening Portland cement grout with shrinkage compensators for wind turbines, bridges and equipment; 110 MPa at 28 days.
Non-shrink fibre-reinforced class R3 mortar for repairing concrete and reinforced concrete by wet spraying, including in large volumes; from 35 MPa.
Acrylic resin grout for fixing equipment with dynamic loads and rails; applied at temperatures from −10 to +25 °C.
Non-shrink fibre-reinforced R4 mortar in 25 kg bags for repairing bridges, tunnels, dams and columns; compressive strength from 55 MPa at 28 days.
Non-shrink fibre-reinforced R4 mortar for repairing bridges, tunnels, dams and columns; compressive strength at 28 days at least 60 MPa.
Highly filled cold-curing epoxy for filling anchor pockets and grouting under turbines, compressors and pumps; 100 MPa in 7 days.