Sazilast 53 — high-strength thiokol joint sealant
Thixotropic polysulfide sealant for joints in concrete, bridges, tunnels and metal roofs; tensile strength at break at least 0.7 MPa.

The grey-label version of Sazilast 25 is a two-component non-shrinking polyurethane sealant for facade panel joints. The cured joint can be painted with both water-based and solvent-based facade paints. Joint movement is up to ±25%, elongation at break is at least 350%, service is from −60 to +70 °C, and the predicted service life is 15 conventional years. The technical description expressly excludes roof elements and joints designed for prolonged contact with water.
| Manufacturer | Sazilast (SAZI) — OOO PK “SAZI” |
|---|---|
| Type | joint sealants |
| Use | joints and junctions, bridge structures |
| Base | two-component non-shrinking polyurethane sealant (A — polyol, V — polyurethane prepolymer) |
| Colour | white, grey |
| Packaging | 10.5 kg kit |
| Application method | mix components A and V with a low-speed drill at 300–350 rpm for at least 10 min; in cold weather condition to +15…+25 °C before mixing; do not add solvents or water; substrate damp but not wet, cleaned; a compressed polyethylene foam backer rod is placed in the joint (no three-sided adhesion); apply by spatula; working layer from 3 mm to 1/2 of the joint width |
| Application temperature | from −15 to +40 °C |
| Curing | pot life at least 6 h at 23 °C; curing 48 h at 23 °C |
| Key properties | permissible movement amplitude ±25%; nominal tensile strength at break at least 0.25 MPa; elongation at break at least 350% (on joint specimens); cohesive failure; Shore A hardness after 24 h 20–30; flow not more than 2 mm; density 1.65 g/cm³; service from −60 to +70 °C; predicted service life 15 conventional years; can be painted with water-based and solvent-based facade paints |
| Layer thickness | working layer at least 3 mm, not more than 1/2 of the joint width |
| Consumption | 99 g/linear m (20 mm joint, 3 mm layer) |
| Shelf life | 6 months at −20…+30 °C in undamaged packaging, protected from moisture, dust and direct sunlight |
| Standards | STO 038-37547621-2016; GOST R 59522-2021, classes 1 and 2P |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Thixotropic polysulfide sealant for joints in concrete, bridges, tunnels and metal roofs; tensile strength at break at least 0.7 MPa.
Thixotropic sealant for vertical and inclined joints of bridges and tunnels under mechanical load; tensile strength at break from 1.5 MPa.
Thixotropic polysulfide sealant for vertical and overhead joints of bridges, tunnels and roofs; applied at temperatures from −15 to +40 °C.
Ready-to-use polyurethane sealant for panel joints, standing-seam roofs, floor joints and sandwich panels; joint movement ±25%.
Two-component facade sealant for panel joints and cracks in above-ground parts of buildings; classic formulation, applied from −15 to +40 °C.
Free-flowing polysulfide sealant for pouring into horizontal and hard-to-reach joints of roofs, roads, bridges and tunnels; elongation at least 200%.