Vetonit Remokor-Krit — polyurethane polymer concrete for expansion joints
Three-component polyurethane polymer concrete for transition zones and expansion joints of bridges and car parks; vehicle traffic after 4–6 h.

Vetonit remokor LS-60 is intended for urgent repair with fast reopening to traffic: at +20 °C foot and vehicle traffic is allowed after 2–3 h, when the compressive strength reaches at least 15 MPa. The rapid-hardening class R4 mix is poured into formwork at air temperatures from −10 to +18 °C; in frost the formwork is insulated from the outside. The mortar is used on airfield and road pavements and industrial floors and for repairing expansion joints; at 28 days the strength reaches 60 MPa, water impermeability W16.
| Manufacturer | Vetonit — OOO “Saint-Gobain Stroitelnaya Produktsiya Rus”, Arzamas |
|---|---|
| Type | pourable repair mortars |
| Use | roads and airfields, floors, industrial buildings, hydraulic structures and dams |
| Base | dry mix based on high-strength cements, graded sand and special additives with polymer fibre; non-shrink, rapid-hardening, non-segregating, high-flow compound |
| Colour | grey |
| Packaging | three-ply paper bag with a polyethylene middle ply, 25 kg |
| Application method | clean the concrete, remove weak areas (grinding, milling, sandblasting, shot blasting), substrate roughness at least 5 mm; at above-zero temperatures dampen 24 h beforehand and before the work, at sub-zero temperatures — do not dampen; mix an amount that can be used within 10–20 min; pour the dry mix into the water, mix for at least 3 min, pause 1 min, remix; temperature of the ready mortar +24…+26 °C; pour into strong, watertight formwork soaked with water or with a moisture-proof surface, in frost insulate the formwork from the outside; pour from one side continuously, without vibration; for a layer thicker than 50 mm add washed gravel (crushed stone) 5–10 mm (5–20 mm) at 50–60 % of the dry mix weight |
| Application temperature | –10…+18 °C (air) |
| Curing | keep moist, protect from precipitation, sun and wind for 24 hours; a film-forming curing compound may be used; at sub-zero temperatures hardening and strength gain slow down |
| Key properties | class R4; maximum aggregate size 3 mm; water demand 3.3–3.7 l per 25 kg (13.5–14.5 %); working time 10–20 min; compressive strength at least 15 MPa (2–3 h), 20 MPa (1 day), 40 MPa (7 days), 60 MPa (28 days) (actual 33.0 / 43.2 / 53.3 / 86.4); flexural tensile strength at least 2 MPa (2–3 h), 4 MPa (1 day), 8 MPa (28 days) (actual 4.3 / 6.5 / 14.8); compressive modulus of elasticity at least 20 GPa (actual 41.6); bond strength to the substrate at least 2 MPa (actual 3.1); after restrained shrinkage 2.6 MPa, after restrained expansion 2.7 MPa; frost resistance grade at least F₁600 / F₂200; water impermeability at least W16 (actual W20); chloride ions no more than 0.1 %; carbonation resistance no more than 2.07×10⁻⁴ cm2/s (actual 1.2×10⁻⁷); chloride ion penetration resistance (0–2 mm, 28 days) no more than 0.08 N/mm2; combustibility group NG; foot and vehicle traffic after 2–3 h at +20 °C; service in exposure classes X0, XC1-4, XD1-3, XS1-3, XF1-4 |
| Shelf life | 6 months from the date of manufacture in factory packaging in a dry room at relative humidity no more than 60 % |
| Standards | STO 56846022-004-2024 “Dry repair mixes”; GOST R 56378-2015 (declaration); declaration of conformity ROSS RU D-RU.RA01.V.39814/26; certificate of conformity to fire safety requirements RU C-RU.PB37.V.01230/24; SGR KG.11.01.09.008.E.000345.01.25 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Three-component polyurethane polymer concrete for transition zones and expansion joints of bridges and car parks; vehicle traffic after 4–6 h.
Rapid-hardening fine-grained class R3 mix for urgent repair and finishing of reinforced concrete on walls and ceilings at temperatures down to −10 °C.
Fine-grained thixotropic class R4 mix with increased crack resistance for repairing reinforced concrete on walls and ceilings.
Thixotropic non-shrink class R4 mix for repairing beams, bridge slabs, pylons and piers by hand or by spraying; 60 MPa compressive.
Fine-grained thixotropic class R3 mix for finishing repair of reinforced concrete and for eliminating pores and cavities on walls and ceilings; W8.
Fine-grained thixotropic class R3 mix for levelling, finishing and protecting reinforced concrete against aggressive media; 40 MPa compressive, W12.