Gidroteks-L (elastic paint-on) — cement-polymer waterproofing
Elastic paint-on coating for structures with vibration and dynamic loads: pools, tanks, basements; elongation 10–12%.
The joint mix of the Gidroteks system fills opened-up floor–wall and ceiling–wall junctions, cold construction joints, concrete block joints, service penetrations, technological openings and cavities to their full depth. It is used when there is no active water seepage, and the main waterproofing is done no earlier than 3 days after filling; the compound is not suitable for expansion and temperature joints. The non-shrink material has a watertightness grade of at least W16, compressive strength of at least 45 MPa and bond to concrete after 28 days of 2.8 MPa.
| Manufacturer | Gidroteks — OOO “Gidroteks-SPb”, Saint Petersburg |
|---|---|
| Type | coating waterproofing |
| Use | joints and abutments, foundations and basements |
| Base | dry dispersed capillary penetrating waterproofing building mix: Portland cements, aggregate, complex chemical additives; non-shrink, cement-based, solvent-free |
| Colour | grey (grey dry dispersed mix) |
| Packaging | 25 kg polypropylene bags; 4 and 15 kg polymer buckets |
| Application method | for repair and sealing of stabilised joints and junctions (floor–wall, ceiling–wall), cold construction joints, concrete block joints, service penetrations, technological openings, surface defects (cavities deeper than 20 mm, cracks) in the absence of active water infiltration; open up joints at right angles to a depth and width of at least 20 mm (20×20 mm chase along the entire length), brick masonry joints — to a depth of at least 5 mm, service penetrations — to a depth of 50–70 mm and a width of at least 50 mm from the edge of the sleeve around the entire circumference; remove foreign inclusions (reinforcement, embedded parts) by opening up to a depth of at least 20 mm, clean exposed reinforcement of concrete and rust; clean the opened-up areas and saturate them with water; water 16% of the mix weight (4 l per 25 kg), water temperature 18–20 °C; mix by hand or with an electric mixer for 5–7 min, technological pause 5 min, re-mix for 5–7 min without adding water; during work, stir without adding water; working time 40–60 min; fill to the full depth, form fillets at right-angle and acute-angle junctions; not for expansion and temperature joints; main waterproofing — no earlier than 3 days after filling |
| Application temperature | not below +5 °C (ambient air) |
| Curing | no special care required under normal conditions; in hot and dry climates do not allow the hardened mortar to dry out for 3 days (spraying with water, covering) |
| Key properties | watertightness grade at least W16 (GOST 12730.5); concrete with a 20 mm thick filling: watertightness under positive pressure >W16, under negative pressure W14 (uncoated concrete W2); increase in the watertightness of joints and junctions by at least 2 steps compared with conventional filling (GOST 31357-2007); flexural tensile strength after 28 days at least 6.0 MPa, compressive strength at least 45 MPa (GOST 310.4); bond strength to concrete at least 1.9 MPa (GOST 31383), after 28 days 2.8 MPa; frost resistance at least 200 cycles (GOST 10060.1), of coated concrete 300 cycles (uncoated 150); diffusion permeability to CO2 — impermeable; reduces chloride ion permeability; chemical resistance coefficient (GOST 25246): 40% aluminium sulphate 0.79, 5% HCl 0.61, 10% NaCl 0.72, 10% NaOH 0.77, acetone 0.90, diesel fuel 0.82; non-shrink; fire-safe; service temperature −40…+90 °C |
| Layer thickness | chase at least 20×20 mm; brick masonry joints — at least 5 mm; service penetrations — depth 50–70 mm |
| Consumption | 0.9–1.0 kg per 1 linear m of joint (in terms of dry mix) |
| Shelf life | 12 months in polypropylene bags, 18 months in polymer buckets; store in dry closed warehouses in the manufacturer's packaging, preventing moistening; at temperatures above +30 °C protect from direct sunlight; bags on wooden pallets 15 cm above the floor, max 8 tiers, cover the pallets with dense polymer film |
| Standards | TU 5716-001-02717961-93 as amended; GOST 31357-2007; GOST 34669-2020; declaration of conformity ROSS RU D-RU.RA01.V.03737/26 dated 16.02.2026, valid until 15.02.2029 |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Elastic paint-on coating for structures with vibration and dynamic loads: pools, tanks, basements; elongation 10–12%.
Ready-to-use water-based latex mastic for WCs, bathrooms, pools, balconies and terraces; watertightness W10, tiling after 12 h.
Universal penetrating mix for foundations, tanks, pools and bridges without active leaks; grade W10, frost resistance 300 cycles.
Rapid-hardening mix for eliminating pressurised leaks in cracks, joints and openings of underground structures; the leak is stopped in 0.3–5 min.
Non-shrink plaster mix for levelling and waterproofing concrete and masonry in basements, bathrooms and showers; watertightness grade W8.
Penetrating mix for basements, foundations and bridge structures with constant water seepage; watertightness grade at least W16.