CarbonWrap® Lamel T-50 CFRP laminate (T-50/83, T-50/120) — polyurethane matrix
Polyurethane-pultruded CFRP laminate 83 or 120 mm wide for strengthening beams, bridges and industrial structures; rolls of 11 linear m.
CarbonWrap Grid 150/1200 is a grid of 12K carbon yarn with a 10 × 20 mm mesh that is embedded in a fresh mineral-based repair mortar, after which a covering layer is applied. This reinforcement is used on bridge structures, in tunnels, collectors and underground structures, on columns, silos and tanks, for seismic retrofitting and for the repair of historic buildings. The breaking strength of the grid is at least 2600 MPa longitudinally and 2100 MPa transversely; for use with the grid the manufacturer specifies CarbonWrap Repair ST and FS repair mortars.
| Manufacturer | CarbonWrap — OOO “Nanotekhnologicheskiy tsentr kompozitov”, Moscow |
|---|---|
| Type | composite strengthening |
| Use | bridges and overpasses, tunnels and metro, tanks and treatment plants, columns and beams |
| Base | grid of high-strength carbon fibres, mesh 10 × 20 mm; warp and weft — 12K carbon yarn |
| Packaging | roll of 50 m, width 1200 mm, 1 roll per cardboard box |
| Application method | external or internal reinforcement; remove plaster, coatings and paints, degrease; restore damaged areas; remove dust with an industrial vacuum cleaner, dampen to a matt-damp state without runs; apply the mineral-based repair mortar with a smooth steel trowel, embed the grid in the layer before it sets, then apply a covering layer that fully covers the grid |
| Key properties | mesh size 10 × 20 mm; breaking strength at least 2600 MPa in the longitudinal direction and at least 2100 MPa in the transverse direction (tests and calculation per the method of TU 1916-043-38276489-2017) |
| Shelf life | unlimited; in a dry closed room, in the original closed packaging |
| Standards | TU 23.99.14-043-38276489-2017 (TU 1916-043-38276489-2017) |
Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.
Polyurethane-pultruded CFRP laminate 83 or 120 mm wide for strengthening beams, bridges and industrial structures; rolls of 11 linear m.
Bidirectional carbon fabric of 6K yarn for repair and seismic retrofitting of reinforced concrete, masonry and reinforced masonry, and steel structures.
Epoxy primer for treating concrete, reinforced concrete and masonry before installing the CarbonWrap system; pot life at least 90 min.
Non-shrink rapid-hardening mix for fast repair of concrete, masonry and cellular concrete, including under CarbonWrap Grid; 30 MPa after one day.
Unidirectional carbon tape on 24K yarn for strengthening slabs, bridge span beams, columns and pylons; width 150, 300 or 600 mm.
Unidirectional carbon tape for the CarbonWrap external reinforcement system, in rolls 150, 300 and 600 mm wide; fibre strength over 4.9 GPa.