Supply across Uzbekistan and to Kyrgyzstan, Tajikistan and Turkmenistan +998 93 815 00 53 Telegram sale@coatix.uz
NEOFLAME (Teplokhim)

VUP-2B fire protection paint for reinforced concrete structures

For reinforced concrete, the VUP range has a dedicated paint, VUP-2B. It gives concrete structures fire resistance up to REI150 and is used indoors in a non-aggressive environment and under a canopy at humidity not above 85 %. The surface is pre-treated with GKZh-11 or SOFEXIL-40 water repellent or UKhRA-0501 primer. Before being put into service, the coating is cured for at least 5 days at temperatures above +15 °C and up to 15 days at lower temperatures; indoors the coating serves for 25 years, under a canopy for 10 years or more.

Specifications

ManufacturerNEOFLAME (Teplokhim) — OOO NPP TEPLOKHIM, Dmitrov
Fire protection performanceup to REI150 (concrete structures)
Applicationconcrete and reinforced concrete
Service conditionsindoors in a non-aggressive environment and outdoors under a canopy; humidity not above 85 %, from −60 °C to +60 °C
Basepolyvinyl acetate dispersion, fire retardants, fillers, water
Colourwhite, tinting in pastel shades permitted
Packagingpolyethylene drum, 50 kg
Application temperaturenot below +5 °C; humidity not above 85 %
Dryingintercoat 6 h at 20 °C; curing before service at least 5 days (above +15 °C) or up to 15 days (below +15 °C)
Compatible primers and topcoatsbefore application: GKZh-11, SOFEXIL-40 water repellents or UKhRA-0501 primer
Shelf life12 months; storage and transport not below +1 °C
StandardsTU 2316-032-66828143-2016

Data from the manufacturer’s technical data sheet. The coating system, number of coats and quantity are selected for your project on request.

Other materials by NEOFLAME (Teplokhim)